activTek INDUCT 5000 Manual

Electronic air purification system
Hide thumbs Also See for INDUCT 5000:

Advertisement

Electronic Air Purification System
READ MANUAL CAREFULLY FOR PROPER PROCEDURES AND OPERATION

Advertisement

Table of Contents
loading

Summary of Contents for activTek INDUCT 5000

  • Page 1 Electronic Air Purification System READ MANUAL CAREFULLY FOR PROPER PROCEDURES AND OPERATION...
  • Page 2: Table Of Contents

    INDUCT 750/2000 air purification enhancement system. This unit About activTek INDUCT 5000/10000 ... . 2 is designed to be installed into an existing HVAC Product Contents.
  • Page 3: Product Contents

    Item # US70682 Item # US70679 Item #US70680 (4) Thumb Nuts (2) Thumb Screws Item #36-00214 Item #36-00213 REPLACEMENT PARTS INDUCT activTek INDUCT 5000 activTek INDUCT 10000 5000/10000 Ozone free Ballast Plate ActivePure® Cell Item # US71089 Ballast Removable Cover Ozone ActivePure®...
  • Page 4: Installation Requirements

    The duct work around the installation area should be clean and dry to ensure proper adhesion of the gasket materials and any tape used. Depending on model, one opening (activTek INDUCT 5000) or two openings (activTek INDUCT 10000) approximately 4” (four inches) (10.16 cm) in diameter will need to be cut into the existing duct work to install the unit properly.
  • Page 6 ACTIVTEK INDUCT 5000/10000 - CELL HOLE PLACEMENT TEMPLATE...
  • Page 9 It is recommended for maximum effectiveness that the unit be placed as close to the air handler as possible. NOTE: The illustrations are shown installing an activTek INDUCT 10000. The procedures shown in this manual apply to both units, unless otherwise indicated. Using the appropriate template included, mark location for installation.
  • Page 10: Maintenance/Uv Lamp Indicator

    WARNING: Hard wiring unit into HVAC system should be done by a licensed HVAC installer or qualified electrical contractor only. Connect wires coming from the activTek INDUCT 5000/INDUCT 10000 unit to the fan relay as follows: NOTE: All units come standard with a blunt cord.
  • Page 11: Changing The Activepure® Cell

    WARNING: UV Light in operation. Disconnect unit from power supply before servicing. Failure to follow warnings may result in severe eye damage. Remove the activTek INDUCT ballast assembly by removing the four (4) thumb screws and sliding the unit out.
  • Page 12: Changing The Ballast

    Remove the wires from ballast by pressing a small screwdriver into the wire release: • INDUCT 10000 - 8 wires • INDUCT 5000 - 6 wires To reconnect wiring, insert wire into the corresponding color connector. Gently pull back after inserting wire to ensure the wire is properly locked into place.
  • Page 13 CHANGING THE BALLAST (continued) 6. Place new ballast into original 7. Replace cover and secure with location and secure using the the original four (4) screws. two (2) nuts removed in step 4. 8. Re-install unit if removed from duct. Reconnect power and check for proper operation (Lamp indicator should be lit when in operation).
  • Page 14: Warranty Information

    ActivePure FROM BREACH OF EXPRESSED OR IMPLIED WARRANTIES, Cell is “ON” 100% of the time. If the INDUCT 5000 or CONDITIONS, GUARANTEES OR REPRESENTATIONS, INDUCT 10000 is connected to the fan circuit where the BREACH OF CONTRACT, NEGLIGENCE OR ANY OTHER ActivePure Cell cycles “ON and OFF”...
  • Page 16 DBG Group Investments, LLC and Medical Equipment (ISM), pursuant to dba activTek Environmental Part 18 of the FCC Rules. These limits are Model: activTek INDUCT 5000/10000 designed to provide reasonable protection against harmful interference in a residential Manufacturer: installation. This equipment generates, uses,...