Table of Contents

Advertisement

Available languages

Available languages

Quick Links

P U R E
Owner's Manual
INNOVATIVE AIR TREATMENT SYSTEM
2' x 2' Ceiling Unit with ActivePure® Certified Space Technology
CAUTION: READ MANUAL CAREFULLY FOR PROPER PROCEDURES AND OPERATION.
EngFre_65-00636_VA-00983_1017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PURECLOUD and is the answer not in the manual?

Questions and answers

Summary of Contents for activTek PURECLOUD

  • Page 1 P U R E Owner’s Manual INNOVATIVE AIR TREATMENT SYSTEM 2’ x 2’ Ceiling Unit with ActivePure® Certified Space Technology ™ CAUTION: READ MANUAL CAREFULLY FOR PROPER PROCEDURES AND OPERATION. EngFre_65-00636_VA-00983_1017...
  • Page 2 • Keep hair, clothing, fingers, and all parts of body away from openings. • To reduce the risk of electric shock, do not expose to water or rain. READ AND SAVE THESE INSTRUCTIONS Please record the name and phone number of your activTek Distributor: Name ______________________________________________________________ Phone _____________________________________________________________...
  • Page 3: Table Of Contents

    This unit is designed to be mounted into a ceiling. Please read and follow all safety warnings and service procedures outlined in this manual. Use only genuine activTek replacement parts available from your activTek Distributor. If you have any questions concerning this or any activTek product, please contact your activTek Distributor. PRINCIPLES OF OPERATION Nature cleanses the air with lightning and rain.
  • Page 4: Specifications

    SPECIFICATIONS Bulb: Type UV-C, 26 Watts Electrical: 110-120V 60Hz .75A Dimensions: 24” x 24” x 5” 220-240V 50Hz .3A 60.96cm x 60.96cm x 12.7cm Motor: Impedance-Protected Weight: 12 lbs (5.44 kg) Mechanical: 100CFM (Fan) 2.83 m /min Power Switch Electrical Box 5 inches 24 inches 24 inches...
  • Page 5: Installation

    INSTALLATION The PureCloud is designed to be mounted in place of a standard 2’ x 2’ ceiling tile. Installation is only to be performed by a qualified electrician. • The PureCloud must not be installed in a ceiling thermally insulated to a value greater than R40.
  • Page 6: Service & Maintenance

    SERVICE & MAINTENANCE Service should only be performed by a qualified electrician. Make sure the power switch is turned off and wiring is disconnected prior to handling. 1. Remove 8 bolts to disassemble the backing from the ventilation panel. 2. Remove screws holding the ActivePure Cell in place.
  • Page 7: Warranty

    OR CONSEQUENTIAL DAMAGES time periods: WE SHALL NOT IN ANY CASE BE LIABLE FOR SPECIAL, • PureCloud within three (3) years of date of purchase. INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM BREACH OF EXPRESSED OR IMPLIED WARRANTIES, • ActivePure Cell and Lamp within one (1) year from the CONDITIONS, GUARANTEES OR REPRESENTATIONS, date of purchase.
  • Page 8 Title: Vice President of Product equipment and receiver. Development and Manufacturing Connect the equipment into an outlet on a Date: 10/23/2017 circuit different from that to which the receiver is connected. Consult your activTek Distributor or an experienced radio/TV technician for help.
  • Page 9 P U R E Manuel de l’utilisateur SYSTÈME INNOVATEUR DE PURIFICATION DE L’AIR Appareil de plafond de 2 pi x 2 pi doté de la technologie Certified Space Technology ActivePure ™ ® ATTENTION : LIRE LE MANUEL ATTENTIVEMENT POUR CONNAITRE LES PROCÉDURES ET LE FONCTIONNEMENT APPROPRIÉS.
  • Page 10 Ne pas suivre les mises en garde peut entraîner des dommages sérieux aux yeux ainsi que provoquer des décharges électriques. Veuillez inscrire le nom et le numéro de téléphone de votre distributeur activTek : Nom ______________________________________________________________ Tél. ________________________________________________________________ Veuillez inscrire le numéro de série de votre produit :...
  • Page 11: Introduction

    N’utilisez que les pièces de remplacement activTek authentiques, disponibles auprès de votre distributeur activTek. Si vous avez la moindre question par rapport à ce produit ou tout autre produit activTek, veuillez contacter votre distributeur activTek. PRINCIPES DE FONCTIONNEMENT La nature nettoie l’air avec des éclairs et de la pluie.
  • Page 12: Spécifications

    SPÉCIFICATIONS Lampe : Type UV-C, 26 watts Électrique : 110-120 V 60 Hz 0,75 A Dimensions : 24 po x 24 po x 5 po 220-240 V 50 Hz 0,3 A 60,96 cm x 60,96 cm x 12,7 cm Moteur : Protégé...
  • Page 13: Installation

    INSTALLATION PureCloud est conçu pour être installé à la place d’un carreau de plafond de 60,96 cm x 60,96 cm (2 pi x 2 pi). L’installation ne devrait être effectuée que par un installateur qualifié. • PureCloud ne doit pas être installé dans un plafond dont l’isolation thermique dépasse R40.
  • Page 14: Service Et Entretien

    SERVICE ET ENTRETIEN L’entretien ne devrait être effectué que par un installateur qualifié. Avant toute manipulation, s’assurer que l’interrupteur d’alimentation est réglé sur OFF (arrêt) et que le filage est débranché. 1. Retirer 8 boulons pour retirer l’endos du panneau de ventilation. 2.
  • Page 15: Garantie

    Le non-respect de ces exigences annulera cette garantie. fuites ou autres dommages causés par l’ e au. L’ e ntretien de votre appareil PureCloud par des parties autres que nos POUR LES ÉTATS-UNIS SEULEMENT représentants autorisés et/ou l’utilisation de pièces autres que les pièces d’...
  • Page 16 DBG Group Investments, LLC aux limites pour les équipements industriels, scientifiques et médicaux (ISM), conformément Modèle : PureCloud 120 V (A1021A) à la section 18 des règles de la FCC. Ces PureCloud 230 V (A1021B) limites sont conçues pour apporter une protection raisonnable contre les interférences...

Table of Contents