5.10.13 Reset System Data - RESEARCH CONCEPTS RC2000C Manual

Az/el tracking antenna controller
Hide thumbs Also See for RC2000C:
Table of Contents

Advertisement

RC2000C Az/El Tracking Antenna Controller
The purpose of this feature is to keep an operator away from the modes and CONFIG mode items that
can change the contents of the controller's non-volatile memory.
When the Expert Access screen is displayed, the present state of the Expert Access Flag is displayed in
the data entry field. A display value of 1 indicates that the Expert Access Flag is set, and a value of 0
indicates that the flag is reset. To toggle the state of the flag, the user must key in a 5 digit code at the
prompt followed by the ENTER key. This code is found in a removable Appendix at the end of this
manual. If the information is lost, call the factory for assistance.
EXPERT ACCESS (0-OFF, 1-ON):
ENTER CODE TO TOGGLE

5.10.13 Reset System Data

The Reset System Data CONFIG mode data item is used to reset the controller's non-volatile memory.
When this occurs, the azimuth and elevation limits are invalidated, and most of the various CONFIG
mode items are initialized to a default value. This operation is usually performed at the factory. Access
to this item is allowed only when the Expert Access flag is set. To reset the system memory, the user
must key in the same 5 digit code used for Expert Access, followed by the ENTER key.
RESET SYSTEM DATA:
ENTER CODE
Following are the default values that are assigned to non-volatile memory on system reset. A space is
provided to record the values of the CONFIG mode items that are assigned by the user.
CONFIG Mode Item
Azimuth Position Count:
Azimuth CCW Limit:
Azimuth CW Limit:
Azimuth Limit Checksum:
Elevation Position Count:
Elevation Down Limit:
Elevation Up Limit:
Elevation Limit Checksum:
AutoPol Enable:
AutoPol Vpol Level:
Simultaneous Az/El Enable:
Remote Mode Enable:
Comm Port Address:
Comm Baud Rate:
Azim Slow Speed:
Elev Slow Speed:
Research Concepts, Inc. • 9501 Dice Lane • Lenexa, Kansas • 66215 • USA
Chapter 5
Modes Function Description
1 CONFIG
ENT,BKSP,SCRLL ^v
0
CONFIG
ENT,BKSP,SCRLL ^v
Default Value
5000
4999
5001
Invalid
5000
4999
5001
Invalid
0
1 (Vertical)
0 (Disabled)
0 (Disabled)
50
9600
253 (Disabled)
253 (Disabled)
Record Actual
Value
_________________
_________________
_________________
_________________
_________________
_________________
_________________
_________________
_________________
_________________
_________________
_________________
www.researchconcepts.com
61

Advertisement

Table of Contents
loading

Table of Contents