Figure 1, the relays would chatter. On the RC2000, slow speed movement may be disabled by setting
the azimuth and elevation slow speed codes to 254. On the RC1000, slow speed movement is disabled
by setting the slow speed index to the highest possible value.
When controlling AC or large DC motors with either the RC1000 or RC2000, it may be necessary to
change the controller's ANTI-REVERSAL DEADBAND, COAST, RETRY COUNT, and MAXIMUM
POSITION ERROR parameters. These parameters control the movement of the antenna.
Voltage Dropping Resistor
(to match the output of the RC2000
to the Relay Coils)
36 Volts DC
output
AZ:
908 EL:
390 POL:
ON
SPEED:SLOW SAT:GALAXY 6
OFF
Research Concepts, Inc.
RC2000 Dual Axis Antenna Controller
tm
w/ ADAPTI-DRIVE
RC2000 Antenna Controller
When the antenna has been moving in one direction, it must be allowed to come to a complete stop
before it is commanded to move in the opposite direction, or position pulses may not be accumulated
properly. The ANTI-REVERSAL DEADBAND specifies the minimum number of milliseconds between
antenna movements in opposite directions. On the RC2000A the user may specify four deadbands,
azimuth fast, azimuth slow, elevation fast, and elevation slow. For the RC2000C the user can specify
two deadbands - Az/El fast and Az/El slow. When the circuit of Figure 1 is used, the fast and slow
deadbands for a given axis should be set to the same value.
When the antenna is performing an automatic move to a target position, the antenna drive signals are
released before the antenna reaches the target position. The idea is that the drive signals are released
and the antenna coasts into position. The COAST parameters specify the number of position counts
before a target position is reached where the drive signals are released. There are unique COAST
parameters for each axis on the RC2000.
When the antenna is performing an automatic move, the controller will make a number of attempts to hit
the target position. The RETRY COUNT parameter specifies how many attempts the controller will
make to reach the target position. The MAXIMUM POSITION ERROR parameter specifies the
maximum allowable error about the target position. If the antenna comes to a stop within MAXIMUM
POSITION ERROR counts of the target position, the controller will not attempt to make another move to
get the antenna closer to the target position.
On the RC2000 these parameters may be set by the user via CONFIG mode. On the RC1000 these
parameters are programmed into the controller's EPROM memory and can only be changed at the
factory.
Polarization Control
If the polarization is controlled with something other than a polarotor, an interface for a polarization
motor is necessary. If control for a polarization motor is needed, use the RC2000 with the RC2KPOL
option. For a single axis antenna this will mean that the elevation control capability of the RC2000 is
not used. The polarization control can use a scheme similar to that used for the azimuth and elevation
Research Concepts, Inc. • 9501 Dice Lane • Lenexa, Kansas • 66215 • USA
D1
,R.
R
D2
AZ1
AZ2
1
2
3
55H
MANUAL
N
Mode
CCW
CW
4
5
6
Scroll
W
E
Up/Yes
7
8
9
Scroll
S
Dn/No
H
V
.
0
GEO
Enter
Stop
Speed
BKSP
AZ CCW Contact
Figure 1.
Appendix F
AC or Large DC Motors
AZ CCW Relay
Coil
The limit switches open
when the limit is reached.
D3
AZ CW Relay
AZ CCW
Coil
Limit Switch
POWER
CONTACTOR
AZ CW Contact
Closure
Closure
D4
AZ CCW Current
AZ CW
Limit Switch
AZ CW Current
230 Volts AC
(3-phase)
input
to Azimuth
3-phase
AC Motor