3.2 Controller Settings of Screen Design Software

GOT NET No.
GOT Station No.
GOT Communication Port No.
Retry (Times)
Startup Time (Sec)
Timeout Time (Sec)
Delay Time (ms)
GOT Ethernet Setting
Update GOT Ethernet Standard Port Setting
GOT IP Address
Subnet Mask
Default Gateway
Peripheral S/W Communication Port No.
Transparent Port No.

3.3 Ethernet Controller Settings of Screen Design Software

Host
Net No.
1
*

3.4 Overlap Window Settings of Screen Design Software

To close the window screen when switching base screens, the [Close the window when switching base
screens] box is checked in [Detail Setting] of Overlap Window in [Screen Switching/Window Setting].
The [Disable the touch operation of a screen on the back] box is checked for overlap window 3.

3.5 Graphics Mode (Graphics Setting)

The graphics mode of this sample screens is GOT Graphic Ver.2.
The screen design used in this sample is [Basic-Gray].
In GOT Graphic Ver.2, the background of overlap windows become semitransparent.

4. Inverter FR-F800-E

4.1 Inverter FR-F800-E Communication Settings

Operation mode selection
Communication startup mode selection
NET mode command source selection
PU mode command source selection
Ethernet communication network number
Ethernet communication station number
Ethernet function selection 1
Ethernet IP address 1
Ethernet IP address 2
Ethernet IP address 3
Ethernet IP address 4
Set the parameters above from the operation panel (FR-DU08) or FR Configurator2*1.
After the settings, the inverter will start with NET operation mode when the power is on (reset). To change
parameters via GOT, switch the inverter to the NET operation mode.
Pressing the
*1: Only the simple mode parameter will be displayed in default settings for the F800 FM type. To display
simple mode + extended parameters, set "0" to the Pr.160 "User group read selection".
Item
Item
Station
1
1
Item
key on the inverter body switches between the NET and PU operation modes.
Set value
1
18
5036
3
3
3
0
Set value
Checked
192.168.3.18
255.255.255.0
0.0.0.0
5015
5014
Unit Type
IP Address
FREQROL
192.168.3.50
Parameter
Pr.79
Pr.340
Pr.550
Pr.551
Pr.1424
Pr.1425
Pr.1427
Pr.1434
Pr.1435
Pr.1436
Pr.1437
7/83
Remarks
Remarks
Port No.
Communication
5001
UDP
Set value
0
10
5
2
1
1
5001
192
168
3
50
BCN-P5999-1067