Exterior Installation - DuraVent DURATECH PREMIUM Installation And Operation Instructions Manual

Factory-built 650c chimney 6”, 7”, & 8” dia
Table of Contents

Advertisement

6

EXTERIOR INSTALLATION

TEE & WALL SUPPORT
Three wall supports are available. All three are
adjustable (ATSC), (URES), and (ATS)
INSTALLATION NOTES
If possible, install an interior chimney as it will pro-
vide better performance than an exterior chimney.
In areas with continuous temperatures below -18°C
(0°F), the use of an exterior chimney may result in
operating problems such as poor draft, excessive
condensation of combustion products and rapid
accumulation of creosote when connected to a
wood burning appliance. If you do install an exteri-
or chimney, we recommend that you surround the
chimney within an insulated enclosure.
1. Maintain 2" clearance to combustible materials.
Do not fill the 2" space around the chimney with
insulation or any other material.
2. In exterior installations, the chimney must be
stabilized at 8-foot intervals. A wall band (AWBU)
or Offset Support (URES) can be used for this
purpose.
3. The adjustable supports (ATSC) and (URES) can be
installed either below or above the insulated tee.
4. IMPORTANT: To ensure minimum clearances to
stovepipe, the insulated pipe length (passing
through the wall) must project beyond the inside
wall by a minimum of 5". The maximum projection
length is 24". See Figure 16.
5. The distance between the stove pipe and a parallel
combustible wall or ceiling must not be less than
18". The distance between the horizontal stove
pipe and the unshielded vertical wall through which
it passes must not be less than 7".
6. If an exterior installation is to be enclosed, (see
Figure 20) allow for access to base of tee to fa-
cilitate required cleaning.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
URES
ADJUSTABLE ATSC
24" Max.
5" Min.
WALL THIMBLE
(XRSM)
INSULATED
CHIMNEY
FLUE EXTENSION
(XCA)
WALL STUD
4 in. Nails or #10
x 1-1/4 in. screws
Figure 16
Note: If desired, a 1/2" stainless self-tapping screw
can be used to fix the tee cap in place. Do not pen-
etrate the inner wall of the chimney.
7. The minimum distance between the bottom of the
Support or Tee and any horizontal combustible
(including the ground) is 2".
ATS
ADJUSTABLE
4 in. Nails or #10 x 1-1/4 in.
screws
LEVEL
WALL SUPPORT AND
TWIST-LOCK CAP (TCI)
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dtp

Table of Contents