Transit with metal objects (if there is the Metal Detector)
To allow the entrance in the protected area to a person with metal objects or weapons (for example, security
guards, escorts for valuables) it is necessary to follow this procedure:
1) If entering the user has set the metal detector's alarm off, the operator can turn off the metal detector
with the console, allowing the entrance;
2) If the person, before entering, will ask entrance permission through the intercom, using the console the
operator can turn off the metal detector.
In both cases, the operator has to only switch the metal detector in the ON position.
Door closed to the public
In order to prevent the entrance to the public, during fixed times, it is necessary to turn off the opening button
of the external door using the "Bi-directional/unidirectional exit" command on the console. In this case, the user
has to ask for the entrance through the intercom.
Anti-hostage alarm
The weight check system is set up at 120 Kg of max. threshold by the head office directly (except for customer's
specific request). If there is a weight greater than the above-mentioned value, the exit procedure will be
interrupted and the external door will remain open.
In the meantime, a voice synthesis message will invite to contact the operator through the intercom.
Procedure for the transit of two people
If two people have to transit simultaneously, (or, in any case, with the "Anti-hostage" alarm on) by pressing
the Reset key (Enter key for the digital console) the system will end the entrance procedure.
Opening doors in emergency
The Emergency command on the console allows the simultaneous opening of the doors.
If there is no power supply or if the booth breaks down, it is necessary to use the manual emergency.
In this case, open the door from inside the bank (over the transit area), switch off the power supply using
the ON/OFF switch placed on the electronic logic's rack.
If there is a person inside the booth, and there is no power supply, it is possible to open the external
door manually.
It is important to do this operation after having turned off the booth's main
switch.
Automatic function in emergency.
Should there be a power supply failure (220v) the batteries will start working automatically and will enable
the functions for at least 30 more minutes. After such time the doors will not work. By pushing the on switch
on the main panel it is possible to use an extra energy reserve that will allow some extra door openings.
The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using this information for any purpose other
than the use of the products or the execution of the project to which it refers and from communicating it to third parties without prior written agreement of Automatic Systems.
The document is subject to change without notice.