3.6. Auxiliary board T/O315 connection diagram
Singleboard metal connector
RL 01 ENTRANCE TRANSIT VALIDATION
RL 02 EXIT TRANSIT VALIDATION
RL 03 BOOTH CONTACT IN EMERGENCY
RL 04 CONDITION CONTACT INTERNAL DOOR
RL 05 CONDITION CONTACT EXTERNAL DOOR
RL 06 EXCESSIVE WEIGHT SIGNAL
RL 07 INTERCOM SIGNAL
The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using this information for any purpose other
than the use of the products or the execution of the project to which it refers and from communicating it to third parties without prior written agreement of Automatic Systems.
The document is subject to change without notice.
ClearLock 645
-TM-EN
315W001E
1
2
Ent 7
3
Ent 6
4
Unblock doors
5
Emergency
6
Open external manually
7
Open internal manually
8
Transit not allowed
9
Transit allowed
10
L-
11
L+
12
GND
13
+12 IN
14
GND
15
GND
16
RL 08 No
17
RL 08 Nc
18
RL 08 Com
19
RL 07 No
20
{Value}
RL 01 Com
40
RL 01 Nc
39
RL 01 No
38
RL 02 Com
37
RL 02 Nc
36
RL 02 No
35
RL 03 Com
34
RL 03 Nc
33
RL 03 No
32
RL 04 Com
RL 04 Com
31
RL 04 Nc
30
RL 04 No
29
RL 05 Com
28
RL 05 Nc
27
RL 05 No
26
RL 06 Com
25
RL 06 Nc
24
RL 06 No
23
RL 07 Com
22
RL 07 Nc
21