8. ALARMS

Alarm on
Problem (on
display
the manual)
No water in the
chamber, or
H2O
water pressure
too low
No water in the
drain, or water
H2O.
pressure too
low
No mains gas,
or gas pressure
GAS
too low, or flame
detection failure.
Copyright by Servizio Clienti ANGELO PO Spa
Solution (on the
manual)
Check that mains water
is present or adjust the
pressure; if the problem
persist inform the after-
sales service.
Check that mains water
is present or adjust the
pressure; if the problem
persists inform the after-
sales service.
Press reset button (the
button may have to e
pressed several times); if
the problem persists
inform the after-sales
service.
Note (on the
manual)
Check correct working conditions of
chamber water solenoid valve and
pressure switch. The terminals
Common and Normally Open of
Convection
pressure switch must be connected
cooking
with wires n° 37 and 40 to the power
cycles can still
PCB. Verify the inlet water supply
be carried out.
pressure and the adjustment of the
water pressure reducer (about 1 bar).
Check voltage on the terminal n° 9 of
the power PCB; check the fuse 3,15 A
on the power PCB.
Check correct working conditions of
chamber water solenoid valve and
pressure switch. The terminals
Common and Normally Open of
Convection
pressure switch must be connected
and steam
with wires n° 37 and 39 to the power
cooking
PCB. Verify the inlet water supply
cycles can still
pressure and the adjustment of the
be carried out.
water pressure reducer (about 1 bar).
Check voltage on the terminal n° 10 of
the power PCB; check the fuse 3,15 A
on the power PCB.
Stop cooking
if this
message is
See chapter 4.8 (alarm gas chart)
repeated
more than
once.
Note for Service
120