NOTE
Before contacting Webasto for technical support please collect the following information:
■ Are any error codes displayed?
■ Is the display of the air distributor in normal operation or not? Does it display a temperature from
16 to 30°C?
■ Can you adjust the set point temperature when in cool or heat mode?
■ Is there a "0" shown in the display?
■ Is the display showing a jumbled display?
■ When in fan mode is there any air flow from the air distributor outlets?
■ Can you hear the compressor starting or stopping in heating or cooling mode?
Your help in collecting this information will greatly assist the service team in correcting any prob-
lems. – Thank you.
8

Disposal

Dispose of packaging material as required by standing regulations, separating them for recycling.
The system cannot be disposed off as regular waste.
Dispose the system according the local applicable rules and regulations. Obtain information about
disposal at the city council, the responsible waste station and/or your local Webasto sales partner.
9

Technical Specifications

Parameter
Product name
Manufacturer model name
Power supply
Rated cooling capacity
Rated heating capacity
Input power for cooling
Input power for heating
Rated current for cooling
Rated current for heating
Maximum input power
Maximum current
Operation at ambient temperatures
NOTE
All parameters listed are subject to change without notice and the specifications shown on unit data
plates shall prevail. All values are approximate and subject to change.

10 Wiring schematic

See the „Wiring schematic Cool Top Trail 34" on page 154.
Legend:
Item
Description
1
Control panel
2
Room sensor
3
Outdoor heat exchanger sensor
4
Indoor heat exchanger sensor
5
LED lights module (Option)
6
Fuse 5x20mm, 250V, T5AL or T5AH
7
Compressor

11 CE-Declaration

See the „CE-Declaration Belaire H3400 / Cool Top Trail 34" on page 154.
Cool Top Trail 34
Value
Cool Top Trail 34
Cooling possible at ambient tem-
peratures
Belaire H3400
Maximum design pressure
220-240 V/50 Hz Minimum design pressure
3400 W
Maximum air flow
3000 W
Weight outdoor unit
1350 W
Weight indoor unit
1250 W
Refrigerant charged
5.8 A
Global Warming Potential (GWP) 1774
5.4 A
CO2 equivalent
1700 W
Maximum vehicle inclination an-
gle during operation
7.4 A
Dimensions
-5 °C to +50 °C
Item
Description
4WV 4 Way reversing Valve
ID
InDoor (sensor)
IF
Indoor Fan
OD OutDoor (sensor)
OF
Outdoor Fan
HF
High
MF Medium
Parameter
16 °C to 50 °C
2900 kPa
1840 kPa
374 m
net 45 kg
net 3 kg
R407C/900 g
1597 kg
5° (=8,8%)
See Fig. 03 / Fig. 04
Wiring code
BN
BU
GNYE
RD
YE
Value
/h
3
Wiring Colour
Brown
Blue
Green-Yellow
Red
Yellow