Table 25: SRX340 Services Gateway Chassis Alarm Conditions and Corrective Actions
Component
Alarm Conditions
Boot media
The services gateway boots
from an alternate boot device.
Hardware
The services gateway chassis
components
temperature or chassis is too
on the
warm
services
gateway
The services gateway
temperature is too high, either
because of an internal
overheating condition or
because the maximum
recommended room
temperature has been
exceeded.
Mini-PIM
A Mini-PIM has failed.
Troubleshooting the Power System on the SRX340 Services Gateway
The PWR LED, located on the front panel of the services gateway, indicates the status of the power system.
Action
If the internal flash memory fails at startup, the
services gateway automatically boots itself from
the alternative boot device (USB storage device).
NOTE:
If you configured your services gateway
to boot from an alternative boot device, ignore
this alarm condition.
Reformat the internal flash memory and install
a bootable image. (See the
and Upgrade Guide
and
and Monitoring
Guide)
If you did not configure the services gateway to
boot from an alternative boot device, contact
JTAC.
Check the room temperature. See
Services Gateway Environmental Specifications"
on page
32.
The services gateway shuts down automatically in
4 minutes.
Contact JTAC.
If you must replace the failed Mini-PIM, see
SRX300 Series and SRX550 High Memory
Services Gateway Interface Modules Reference
for information about replacing the Mini-PIMs.
Alarm
Severity
Amber
(minor)
Software Installation
Network Management
"SRX340
Amber
(minor)
Red (major)
Red (major)
71