SRX 3400 Services Gateway
Getting Started Guide
2 February 2009
Part Number: 530-026091-01
Revision 01
This document describes how to install the SRX 3400 services gateway.
About This Guide .............................................................................................3
Step 1: Prepare the Site ...................................................................................5
Rack-Mounting Requirements ...................................................................5
Required Tools ..........................................................................................5
Step 2: Install the Mounting Hardware ............................................................6
Step 3: Install the Device .................................................................................7
Install the Device Using a Lift ....................................................................7
Install the Device Without a Mechanical Lift ...........................................10
Remove Components .......................................................................10
Lift the Chassis into the Rack ............................................................11
Reinstall Components ......................................................................12
Step 4: Connect the External Devices and IOC Cables ...................................12
Connect to a Network for Out-of-Band Management ...............................13
Connect a Management Console .............................................................13
Connect the IOC Cables ..........................................................................13
Step 5: Connect the Ground and Power Cables .............................................14
Connect the Grounding Cable .................................................................14
Connect Power to an AC-Powered Services Gateway ..............................15
Connect Power to a DC-Powered Services Gateway ................................16
Step 6: Perform the Initial Software Configuration ........................................18
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRX 3400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Juniper SRX 3400

  • Page 1: Table Of Contents

    SRX 3400 Services Gateway Getting Started Guide 2 February 2009 Part Number: 530-026091-01 Revision 01 This document describes how to install the SRX 3400 services gateway. Contents About This Guide .....................3 Step 1: Prepare the Site ...................5 Rack-Mounting Requirements ..............5 Required Tools ..................5...
  • Page 2 SRX 3400 Services Gateway Getting Started Guide Safety Warnings ....................22 Compliance Statements for EMC Requirements ..........24 Canada ....................24 European Union ..................24 List of Technical Publications ................24 Requesting Technical Support ...............25 Revision History ....................26...
  • Page 3: Contents About This Guide

    About This Guide About This Guide This guide contains information you need to install and configure the SRX 3400 services gateway quickly. For complete installation instructions, and instructions on installing additional modules such as cards and power supplies, see the SRX 3400 Services Gateway Hardware Guide at http://www.juniper.net/techpubs/...
  • Page 4 By installing different combinations of IOCs and SPCs, you can tailor both the number of network ports and the maximum security processing capacity to suit your network. Table 1 on page 4 describes the minimum system configuration for the SRX 3400. Table 1: Minimum System Configuraton...
  • Page 5: Step 1: Prepare The Site

    CFMs to prevent damage to the device or power supplies. See the SRX 3400 Services Gateway Hardware Guide for information about supported configurations.
  • Page 6: Step 2: Install The Mounting Hardware

    SRX 3400 Services Gateway Getting Started Guide Phillips screwdrivers, numbers 1 and 2 Electrostatic discharge (ESD) wrist strap Step 2: Install the Mounting Hardware The specific mounting hardware required depends on the type of rack being used. Use the appropriate procedure steps to install the mounting hardware for your situation.
  • Page 7: Step 3: Install The Device

    Ensure the rack is in its permanent location and is secured to the building. Ensure that the installation site allows adequate clearance for both airflow and maintenance. For details, see the SRX 3400 Services Gateway Hardware Guide. Load the device onto the lift, making sure it rests securely on the lift platform (see Figure 6 on page 8).
  • Page 8 SRX 3400 Services Gateway Getting Started Guide Figure 6: Load the Device onto the Lift Using the lift, position the device in the rack: For two-post rack mounting, align the bottom hole in each mounting bracket with a hole in each rack rail.
  • Page 9 Step 3: Install the Device Figure 7: Installing the Device in a Two-Post Rack Figure 8: Installing the Device in a Four-Post Rack Rear shelf Install the remaining screws in each mounting bracket. Move the lift away from the rack. Visually inspect the alignment of the device.
  • Page 10: Install The Device Without A Mechanical Lift

    SRX 3400 Services Gateway Getting Started Guide Install the Device Without a Mechanical Lift To install the device without a mechanical lift: Remove Components on page 10 Lift the Chassis into the Rack on page 11 Reinstall Components on page 12...
  • Page 11: Lift The Chassis Into The Rack

    Do not stack removed components. Lay each one on a flat surface. NOTE: For complete instructions on removing device components, see Installing the Services Gateway Without a Mechanical Lift” in the SRX 3400 Services Gateway Hardware Guide. Lift the Chassis into the Rack Lifting the chassis and mounting it in a rack requires two people.
  • Page 12: Reinstall Components

    Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see the SRX 3400 Services Gateway Hardware Guide. Slide each component into the chassis evenly so that it does not become stuck or damaged.
  • Page 13: Connect To A Network For Out-Of-Band Management

    Connect the IOC Cables Have ready a length of the type of cable used by the IOC. For cable specifications, see the SRX 3400 Services Gateway Hardware Guide. If you are connecting a fiber IOC cable, the connector port may be covered by a rubber safety cap.
  • Page 14: Step 5: Connect The Ground And Power Cables

    Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see the SRX 3400 Services Gateway Hardware Guide. Connect the grounding cable to a proper earth ground.
  • Page 15: Connect Power To An Ac-Powered Services Gateway

    ESD points on the chassis. For more information about ESD, see the SRX 3400 Services Gateway Hardware Guide. Locate the power cord or cords you will use to connect the device to AC power.
  • Page 16: Connect Power To A Dc-Powered Services Gateway

    SRX 3400 Services Gateway Getting Started Guide Snap the wire bail over the power cord as shown in Figure 14 on page 16 to prevent the power cord from accidentally disengaging. Dress the power cord appropriately. Verify that the power cord does not block the air exhaust and access to device components or drape where people could trip on it.
  • Page 17 Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see the SRX 3400 Services Gateway Hardware Guide. For each power supply: Remove the clear plastic cover protecting the terminal studs on the faceplate.
  • Page 18: Step 6: Perform The Initial Software Configuration

    SRX 3400 Services Gateway Getting Started Guide Attach the negative (–) DC source power cable lug to the (input) terminal. Secure the cable lug to the terminal on the power supply, first with the square washer, then with the screw. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in.
  • Page 19 Step 6: Perform the Initial Software Configuration Set the root authentication password by entering a cleartext password, an encrypted password, or an SSH public key string (DSA or RSA). [edit] root@# set system root-authentication plain-text-password New password: password Retype new password: password Configure an administrator account on the device.
  • Page 20 SRX 3400 Services Gateway Getting Started Guide Configure basic security policies. [edit] admin@# set security policies from-zone trust to-zone untrust policy policy-name match source-address any destination-address any application any root@# set security policies from-zone trust to-zone untrust policy policy-name then permit Check the configuration for validity.
  • Page 21 Step 6: Perform the Initial Software Configuration file interactive-commands { interactive-commands any; license { autoupdate { url https://ae1.juniper.net/junos/key_retrieval; interfaces { ge-0/0/0 { unit 0 { family inet { address 192.1.1.1/24; ge-0/0/1 { unit 0 { family inet { address 5.1.1.1/24;...
  • Page 22: Safety Warnings

    WARNING: See installation instructions before connecting the device. This is a summary of safety warnings. For a complete list of warnings for this device, including translations, see the SRX 3400 Services Gateway Hardware Guide at http://www.juniper.net/techpubs/hardware/ WARNING: The intrabuilding port(s) of the device is suitable for connection to intrabuilding or unexposed wiring or cabling only.
  • Page 23 Safety Warnings Only trained and qualified personnel should install or replace the device. Perform only the procedures described in this guide or the SRX 3400 Services Gateway Hardware Guide. Other services should be performed by authorized service personnel only. Read the installation instructions before you connect the device to a power source.
  • Page 24: Compliance Statements For Emc Requirements

    SRX 3400 running JUNOS software. All documents are available at http://www.juniper.net/techpubs/ SRX 3400 Services Gateway Hardware Guide—Explains in detail how to install and Hardware Guides maintain an SRX 3400 services gateway. JUNOS Software Interfaces and Routing Configuration Guide—Explains how to...
  • Page 25: Requesting Technical Support

    7 days a week, 365 days a year. Self-Help Online Tools and Resources For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features: Find CSC offerings: http://www.juniper.net/customers/support/...
  • Page 26 Products made or sold by Juniper Networks or components thereof might be covered by one or more of the following patents that are owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440, 6,192,051, 6,333,650, 6,359,479, 6,406,312, 6,429,706, 6,459,579, 6,493,347, 6,538,518, 6,538,899, 6,552,918, 6,567,902, 6,578,186, and 6,590,785.