Setup And Assembly; Mounting Stone Wheel; Installing Water Tank; Support Arm (Optional) - Jet JWS-10 Operating Instructions And Parts Manual

10” slow speed wet sharpener
Table of Contents

Advertisement

6.0 Setup and assembly

The Wet Sharpener must be
disconnected from power during assembly.
Inspect the Wet Sharpener – if any damage is found,
notify your dealer immediately. Do not use a
damaged machine.
Clean all rust-protected surfaces with a mild solvent.
Remove shipping foam: A foam block is inserted
inside the machine to prevent the motor shaft from
resting on the drive wheel during shipment. Remove
storage drawer, turn machine on its side, and
remove the foam block before operating.
The machine should be placed on a stable and level
surface. It can be bolted down if needed.

6.1 Mounting stone wheel

Install stone wheel (C) on shaft. See Figure 5-1.
Place a washer on each side of wheel, and tighten
nut.
Note: The stone has already been trued by the
manufacturer.

6.2 Installing water tank

Install water tank (F) to lower mounting position on
side of machine. See cover photo.
Fill the tank with water up to the "MAX" marked level.
The stone will soak up a lot of water – approximately
0.5L (1/2 qt.) – within the first 15 minutes.
As the stone wears to a smaller diameter, the tank
must be moved to the upper mounting position.

6.3 Support arm (optional)

Install the accessory support arm (M, Figure 5-1) to
the vertical or the horizontal sleeves, depending
upon the specific sharpening to be done. Always
tighten knobs to secure.

6.4 Storage

The machine has an integrated drawer (E, Figure 5-
1) where the standard accessories can be stored for
quick access.
The existing angle measuring device (T, Figure 5-1)
will stick to the magnets on the designated place at
the side of the machine.
The angle measuring device (S, Figure 5-1) has
integrated magnets and will stick to any surface on
the machine body.

7.0 Electrical connections

Electrical connections should
be made by a qualified electrician in compliance
with all relevant codes. This tool must be
properly grounded.
The wet sharpener is prewired for 120V single
phase power, and is supplied with a plug designed
for use on a circuit with a grounded outlet that looks
like the one pictured in A, Figure 6-1.
Before connecting to power source, be sure switch
is in OFF position.
It is recommended that the wet sharpener be
connected to a minimum 10-amp circuit with circuit
breaker or fuse. If using fuses, they should be time-
delay fuses marked "D". Local codes take
precedence over recommendations.
Figure 6-1: plug configurations

7.1 Grounding instructions

1. All Grounded, Cord-connected Tools:
This tool must be grounded. In the event of a
malfunction or breakdown, grounding provides a
path of least resistance for electric current to reduce
the risk of electric shock. This tool is equipped with
an electric cord having an equipment-grounding
conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
Do not modify the plug provided - if it will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface
that is green with or without yellow stripes is the
equipment-grounding
replacement of the electric cord or plug is
necessary, do not connect the equipment-grounding
conductor to a live terminal.
electrician or service personnel if the grounding
instructions are not completely understood, or if
in doubt as to whether the tool is properly
grounded. Failure to comply may cause serious
or fatal injury.
10
conductor.
If
repair
Check
with
a
qualified
or

Hide quick links: