Disassembly Procedure - Aqua Lung FIRST STAGE Service Manual

Table of Contents

Advertisement

DISASSEMBLY PROCEDURE

Note: Before commencing disassembly, consult
the exploded view to check the reference
numbers of all parts requiring replacement.
These parts should all be replaced by new parts
and should not be re-used on the pretext that
the regulator has seen little use since its
manufacture or since its last service.
Attention: Use only the special tool when
removing O-rings in order to avoid damaging the
seal recess. The slightest scratch on a sealing
surface could cause a leak. If a surface should be
damaged then this part should be replaced with a
new one. Do not use any pointed instrument or
metal tool to remove O-rings.
Service Manual 1st stage Legend
Rev. 12/2011
Service manual First stage Legend
1.
Unscrew the hoses from the first stage using the
appropriate spanner. Screw the HP and MP plugs into
the open ports but leave one HP and one MP port free.
2.
Use an 8mm Allen key to unscrew the plug (129603 /
129701 / 129744). Remove the ribbed washer (129611)
and the ring (129623 / 129702 / 129747).
3.
Manually remove the diaphragm (129126).). Turn the
body over to allow the piston (129606) to fall into your
hand.
4. Remove the protector (129609).
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

LegendLegend luxLegend lx