1. This sensor is a non-contact switch intended for header mount / wall mount of an automatic door.
Do not use for an
other applications. This sensor cannot be used for industrial doors or shutters,
y
when used, proper operation and safet
2. When setting the sensor's detection area, make sure there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipments that are
connected to the sensor.
4. Onl
use the sensor as specified in the operation manual provided.
y
5. Be sure to install the sensor in accordance with the local laws and standards of the country in which
the sensor is installed.
6. Before leaving the job site make sure that the sensor is operating properl
owner/operator on proper operation of the door and the sensor.
7. The sensor setting can onl
be changed b
y
changed setting and dales in the maintenance logbook accompan
&
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it ma
cause electric shock or breakdown of equipments.
Danger of electric shock.
y
ED
The following conditions are not suitable for the sensor installation.
- Fog or exhaust emission around the door.
-Wet floor
- Vibrating header or mounting surface.
- Moving objects or a heating radiator in the detection area.
- Highl
reflecting floor or the presence of highl
� m w
y

SPECIFICATIONS

Model
: QA-AXIS II
Cover color
: Silver / Black
Mounting height
: 2.0 (6'7") to 3.5m (11 '5")

Detection area

: See DETECTION AREA
Detection method
: Active Infrared Reflection
Depth angle
: 1st to 3rd rows / -6
to +6
°
adjustment
4th and 5th rows / +26
to +44
°
Power supply
: 12 to 24VAC (±10%)
12 to 30VDC (±10%)
Power consumption : OA-AXIS II < 4VA
Operation LED
: Green / Stand-b
y
Blinking Red / 1st row detection
Red / 2nd row detection
Orange / 3rd to 5th rows detection
ED
The specifications herein are subject to change without prior notice due to improvements.

OUTER DIMENSIONS AND PART NAMES

36(1 7/16")
-- --
/
-
(1) Connector
(2) Mounting holes
(3) Operation LED
(4) Depth angle adjustment screw
(5) Width adjustment screws
(6) Dipswitches
(7) Detection window
(8) Area adjustment tool
1#t@!M#i
CE
result in serious injury or death of a person.
y
cause the improper operation causing death or serious injury of
y
cause the improper operation causing injury of person or damage to
y
mbol.
y
cannot be guaranteed.
y
and instruct the building
y
an installer or service engineer. When changed, register the
y
ing the door.
y
reflecting objects around the door.
y
Output
: QA-AXIS II
1st to 3rd rows / Form C rela
50V 0.3A Max. (Resistance load)
3rd to 5th rows / Form C rela
50V 0.3A Max.(Resistance load)
°
Output hold time
: Approx. 0.5sec.
°
Response time
: < 0.3sec.
Operating temperature : -20 to +55
C (-4 to 131
°
IP rate
: IP44
Weight
: 320g (11.2oz)
Accessories
: 1 Cable 3m (9'1 O")
1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
267(10 1/2")
"
125(4 15/16")
cc
143(1 11/16").
--
"
,-...
--
--
I
- - 1
"'
,:--
;::::
'
I
I
DETECTION AREA
Motion / Presence
detection
Motion detection [
Sensor selling
1st to 3rd rows
4th and 5th rows: +44
The actual detection area ma
object or the floor as well as the entry speed of the object.
*The values of the chart above is of the emitting spots, but not of the detection area.
1. Affix the mounting template at the desired mounting position.
2. Drill two mounting holes of 03.4mm (01 /8").
3. To pass the cable through to the header, drill a wiring hole of 08mm (05/16").
4. Remove the mounting template.
5. Remove the housing cover. Attach the sensor to the mounting surface with two mounting screws.
Header
Sensor
Door
y
Floor
y
F)
°
&CAUTION
of getting caught.
Risk
ED
The sensor mounting position ma
Wire the cable to the door controller properly as shown in the drawing below.
45(1 3/4")
�ra
QA-AXIS II
[mm (inch)]
Lt_
WARNING
Danger of electric shock.
1.Plug the connector of the sensor.
2.Suppl
y
ED
Make sure to connect the cable correctl
(8)
When turning the power ON or after adjusting the settings, do not enter the detection area for more than
10 seconds in order to enable the presence detection.
Do not touch the dipswitches before turning the power ON, otherwise an error occurs. After changing the
dipswitch and/or potentiometer settings, make sure to push the function switch for 2 seconds.
Place the housing cover.
If wiring is to be exposed, break the knockout.
Lt_
WARNING
Danger of electric shock.
□□□□
1st row
□□□□
■■
[
2nd row
3rd row
G
• H
:
: +6
°
:
°
A
2.20 (7'3")
2.50 (8'2")
2.70 (8'10")
0.16 (6")
B
0.14 (6")
0.18 (7")
C
0.42 (1'5")
0.48 (1 '7")
0.52 (1'8")
D
0.82 (2'8")
0.93 (3'1")
1.00 (3'3")
E
1.35 (4'5")
1.54 (5'1")
1.66 (5'5")
F
1.90 (6'3")
2.17 (7'1")
2.34 (7'8")
G
1.51 (4'11 ")
1.33 (4'4")
1.63 (5'4")
H
2.05 (6'9")
2.32 (7'7")
2.51 (8'3")
I
2.78 (9'1")
3.15 (10'4")
3.40 (11'2")
become smaller depending on the ambient light, the color / material of the
y
H
H: Height from the floor to the bottom of the header
Y: Distance between the bottom of header and the sensor.
X: Distance between the door and the mounting surface
Maximum mounting distance (Y)
x----ti
2.00 (6'7")
2.20 (7'2")
0
No limit
0.20 (8")
0.20 (8")
0.05 (2")
0.10 (4")
0.20 (8")
0.20 (8")
0.15 (6")
0.13 (5")
0.15 (6")
-
0.20 (8")
0.11 (4")
-
-
0.25 (10")
0.30 (12")
-
-
Make sure to affix the mounting template as described in the above chart.
Otherwise, ii can be dangerous since there ma
area around the threshold. Install the sensor as low as possible on the header.
be limited depending on the header thickness and the mounting height.
y
��
White
Wh ite Sir.
L 'vellow Sir. Normally open (N.O.)
Gree n Sir. Normally close d (N.C. )
*The outputs from the 3rd row overlaps.
Before starting the procedure, ensure that the power is turned OFF.
When passing through the cable to the hole, make sure not to tear the shield,
otherwise it ma
cause electric shock or breakdown of the sensor.
y
power to the sensor. Adjust the detection area and set the dipswitches. (See ADJUSTMENTS)
to the door controller before turning the power ON.
y
Do not use the sensor without the cover.
When using the cable knockout, install the sensor indoors or use the rain-cover
(Separetel
available) otherwise electric shock or breakdown of the sensor
y
ma
occur.
y
D :
Emitting spots
: Emitting spots
(Can be elminated)
�-� : Detection area
'
[m(feet,inch}]
3.00 (9'10")
3.50 (11 '6")
0.20 (8")
0.23 (9")
0.58 (1'11")
0.67 (2'2")
1.10 (3'7")
1.30 (4'3")
1.85 (6'1")
2.16 (7'1")
2.60 (8'6")
3.03 (9'11 ")
2.11 (6'11")
1.81 (5'11")
2.79 (9'2")
3.26 (10'8")
3.79 (12'5")
4.42 (14'6")
[m (feet,i n ch)]
2.50 (8'2")
3.00 (9'10")
0.20 (8")
0.20 (8")
0.20 (8")
0.20 (8")
0.17 (7")
0.20 (8")
0.13 (5")
0.15 (6")
-
0.12 (5")
-
-
be no presence detection
y
Power supply
Gre
} 12 to 24VAC ±10%
y
_G_ r e �
_ 12 to 30VDC ±10%
y
Commo n (C OM.)
3rd to 5th
Yellow
Normally open (N.O .)
]
rows output
Green
Normally closed (N.C.)
Common (C OM.)
1st to 3rd •
]
rows output

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QA-AXIS II and is the answer not in the manual?

Questions and answers

Summary of Contents for Optex QA-AXIS II

  • Page 1 5. Remove the housing cover. Attach the sensor to the mounting surface with two mounting screws. Header Sensor � SPECIFICATIONS Model : QA-AXIS II Output : QA-AXIS II Door Cover color H: Height from the floor to the bottom of the header...
  • Page 2 Manufacturer European Subsidiary OPTEX Co.,LTD. OPTEX Technologies B.V. � Aiways check the area according to the expected entry speed and determine the appropriate number of rows. 5-8-12 Ogoto Otsu 520-0101, Japan Henricuskade 17, 2497 NB The Hague, The Netheriands When setting motion and motion / presence detection area sparately, make sure that there is no gap TEL.: +81(0)77 579 8700...

Table of Contents