On completion check that the base is stable
even if the frame is subject to movement.
The installer must provide ample
support where the ceiling or support
shelf is not strong enough by
installing cross beams over the joists
or above the shelf to ensure the
frame is quite rigid at its mounting
point.
Extraction
The cooker hood is more effective when used in the
extraction mode (ducted to the outside).
Venting kits may be purchased through your
retailer or DIY store, and must be ducted to an
outside vent of Ø125mm (5") or Ø150mm (6").
For the best performance use the shortest possible
duct run and the minimum number of bends.
Where flexible ducting is fitted it should not be turned
through very tight bends as this may impair the
performance of the hood.
It is recommended a maximum length of 3 metres
with one bend, to be installed, to be reduced metre
for each 90o bend.
If a distance is greater than 3 metres the efficiency
of the hood could be impaired.
The ducting used must be manufactured
from fire retardent material conforming to the
relevant British Standard or DIN 4102-B1.
When the cooker hood is ducted to the outside the
charcoal filter must be removed.

Ducting Connection

Connect the ducting chosen to:
the Ø150mm ducting spigot on top of the
motor housing, or the Ø150-120mm ducting
spigot 9 and secure using the jubilee clips
25.
A Ø120-125mm collar 10 is provided
to fit over the Ø120mm ducting spigot
when 125mm ducting is fitted.
If the room where the cooker hood is to
be used contains a fuel burning
appliance such as a central heating
boiler, then its flue must be of the room
sealed or balanced flue type.
If other types of flue or appliances are fitted
ensure that there is an adequate supply of
air to the room.
The cooker ducting (extraction mode) must
never be connected to central heating flues,
radiators or water heaters etc.