  • Page 1 Technical Information PLUS+1® Connect CS100 IoT Gateway www.danfoss.com...
  • Page 2 Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only Revision history Table of revisions Date Changed October 2020 First edition 0101 © Danfoss | October 2020 BC299456869228en-000101...
  • Page 3: Table Of Contents

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only Contents About this Manual About this manual....................................5 Device elements Device Information..................................6 Indicator elements................................... 6 Type label......................................7 Intended use...................................... 7 Service and support..................................8 Product Conformity CS100........................................9 Compliance with CE................................... 9 Compliance with ECE R-10...............................9...
  • Page 4 Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only Contents Mounting Inside mount....................................23 Top Mount......................................23 © Danfoss | October 2020 BC299456869228en-000101...
  • Page 5: About This Manual

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only About this Manual About this manual This document is part of the product and provides important information on the intended use, safety, installation and operation of the device(s) described below. The manual is intended for qualified...
  • Page 6: Device Elements

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only Device elements This chapter gives an overview of the device elements, functions and describes the intended use. It further lists the available device variants and the product certifications. Device Information The device elements for the CS100 1.
  • Page 7: Type Label

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only Device elements Type label The CS100 type label is located on the side of the enclosure. CS100 type label information • Model • Part number • Serial number •...
  • Page 8: Service And Support

    PLUS+1 Connect CS100 IoT Gateway — Professional Install Only Device elements • Danfoss has no responsibility for any consequences (direct or indirect) caused by failures or malfunctions. • Danfoss has no responsibility for any accidents caused by incorrectly mounted or maintained equipment.
  • Page 9: Product Conformity

    ® Danfoss CS100 is compliant with PLUS+1 ® System Control Platform. Danfoss Telematics features are added in the Remote Interface (Machine information, signal strength, geographical position linked to Google Maps, CAN Status). © Danfoss | October 2020 BC299456869228en-000101 | 9...
  • Page 10: Safety Information

    The integrator of this device is responsible to check and comply with regional directives and requirements. Warning Danfoss strongly recommends that initialization and provisioning of CS100 IoT Gateways be completed outside of machine production processes. It is best practice to de-couple this initialization and provisioning from machine production processes.
  • Page 11: Avoid Property Damage

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only Safety information • When in a hospital or other health care facility, observe the restrictions on the use of cellular communication equipment. Switch CS100 unit off, if instructed to do so by the guidelines posted in sensitive areas.
  • Page 12: Connecting The Supply Voltage

    The device can only be repaired by the manufacturer, it is not field serviceable. Opening the device housing will void the Warranty. Warning To prevent misuse, immediately inform Danfoss in case of loss or theft of the device or the related SIM card that is factory pre-installed on it. 12 | ©...
  • Page 13: Ordering Information

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only Ordering information Part number Device and part number 11230826 CS100 IoT Gateway Related products Related product and part numbers DEUTSCH mating connector bag assembly K29620 (16-20 AWG) Cable (1m) with 8-pin DEUTSCH DTM connector...
  • Page 14: Device Functions

    Danfoss PLUS+1® Connect portal. CS100 devices have an internal non-volatile memory which allow CS100 to store the logged data in case of a cellular outage. When the cellular connection is recovered the logged data are sent to the Danfoss PLUS+1® Connect portal automatically.
  • Page 15: Can Interfaces

    A support for CAN-FD is not possible. Device configuration The CS100 can be remotely configured from the Danfoss PLUS+1® Connect portal to monitor the machine state, performance, and position. Both position and machine data are periodically transmitted and stored to the Danfoss Data Portal.
  • Page 16: Connector

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only Connector CS100 is equipped with: 1x Main connector (CAN Bus, I/O, Power). Main connector The connector functions: • Connecting the device to the CAN bus network • Supplying the device with power •...
  • Page 17: Cs100 Technical Data

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only CS100 Technical Data Electrical Data Electrical data 9 to 36 Vdc DC supply voltage 16 MB Memory buffering capacity 100 V/m EMI/RFI rating Mechanical Data Mechanical data 177 x 86 x 41 mm...
  • Page 18: Multifunction Inputs

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only CS100 Technical Data Multifunction inputs Middle range analog Description Unit Minimum Typical Maximum Comment Minimum discernible voltage — — — Maximum discernible voltage 5.18 5.26 5.33 — Resolution —...
  • Page 19: Outputs

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only CS100 Technical Data Resistance input Description Unit Minimum Typical Maximum Comment Range Ω — 10000 In steps of 1 Ω Measurement error — — 100Ω — — 1kΩ —...
  • Page 20: Plus+1® Connect Portal

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only PLUS+1® Connect portal The CS100 is produced with a pre-installed SIM card and with a default configuration that allows the direct connection of the device to the PLUS+1 ®...
  • Page 21: Packaging And Transport

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only Packaging and Transport IP protection rating IP 67 rating is ensured only with the following guidelines: • Do not expose the device to dust and water if the connectors are not plugged in.
  • Page 22: Cs100 Technical Drawings

    Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only CS100 Technical Drawings CS100 Dimensions CS100 dimensions in mm [in] 177.70 [7.00] 86.10 [3.40] 71.00 [2.80] 162.00 [6.38] 30.42 [1.20] 40.90 [1.61] 2 X Ø 6.3 THRU 9.30 [0.37] 23.0 [0.1]...
  • Page 23 Technical Information PLUS+1 Connect CS100 IoT Gateway — Professional Install Only Mounting The device can be directly bolted into spaced drill holes, see CS100 Technical Drawings on page 22. The device can be mounted in any position, Top Mount on page 23 is recommended.
  • Page 24 Phone: +86 21 2080 6201 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.