Danfoss PLUS+1 Connect CS500 Manual

Danfoss PLUS+1 Connect CS500 Manual

Iot gateway

Advertisement

Quick Links

Technical Information
PLUS+1® Connect
CS500 IoT Gateway
www.danfoss.com

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss PLUS+1 Connect CS500

  • Page 1 Technical Information PLUS+1® Connect CS500 IoT Gateway www.danfoss.com...
  • Page 2 Technical Information PLUS+1® Connect CS500 IoT Gateway Revision history Table of revisions Date Changed October 2021 First edition 0101 © Danfoss | October 2021 BC397226723595en-000101en-000101...
  • Page 3: Table Of Contents

    Electrical Data....................................17 Mechanical Data.....................................17 Interface/Protocol/Certification..............................17 Multifunction inputs..................................18 Outputs......................................19 PLUS+1 ® Connect portal ® Problem with connection to PLUS+1 Connect portal.....................20 Packaging and Transport IP protection rating..................................21 Disposal......................................21 CS500 Technical Drawings © Danfoss | October 2021 BC397226723595en-000101en-000101 | 3...
  • Page 4 Technical Information PLUS+1® Connect CS500 IoT Gateway Contents CS500 Dimensions..................................22 Mounting © Danfoss | October 2021 BC397226723595en-000101en-000101...
  • Page 5: Document Overview

    Technical Information (TI) A TI is comprehensive information for engineering and service personnel to reference. Data Sheet (DS) A DS is summarized information and parameters that are unique to a specific model. © Danfoss | October 2021 BC397226723595en-000101en-000101 | 5...
  • Page 6: Device Elements

    The CS500 type label is located on the side of the enclosure. CS500 type label information • Model • Part number • Serial number • E-mark certification number • CE mark • Country of origin • Traceability code in data matrix code © Danfoss | October 2021 BC397226723595en-000101en-000101...
  • Page 7: Intended Use

    • Danfoss has no responsibility for any consequences (direct or indirect) caused by failures or malfunctions. • Danfoss has no responsibility for any accidents caused by incorrectly mounted or maintained equipment.
  • Page 8 Technical Information PLUS+1® Connect CS500 IoT Gateway Device Elements Caution Warranty will be voided if device is opened. Device is not field serviceable. Do not open the device. © Danfoss | October 2021 BC397226723595en-000101en-000101...
  • Page 9: Product Conformity

    Danfoss CS100 is compliant with PLUS+1 ® System Control Platform. Danfoss Telematics features are added in the Remote Interface (Machine information, signal strength, geographical position linked to Google Maps, CAN Status). Industry Canada certification for use of wireless devices in Canada Australian and New Zealand certification for use of wireless devices ©...
  • Page 10: Safety Information

    The integrator of this device is responsible to check and comply with regional directives and requirements. Warning Danfoss strongly recommends that initialization and provisioning of CS500 IoT Gateways be completed outside of machine production processes. It is best practice to de-couple this initialization and provisioning from machine production processes.
  • Page 11: Avoid Property Damage

    Before any installation of the Control system, turn ignition lock off and disconnect the battery. Before handling the device disconnect externally. Also, disconnect independently supplied output load circuits. © Danfoss | October 2021 BC397226723595en-000101en-000101 | 11...
  • Page 12: Connecting The Supply Voltage

    The device can only be repaired by the manufacturer, it is not field serviceable. Opening the device housing will void the Warranty. Warning To prevent misuse, immediately inform Danfoss in case of loss or theft of the device or the related SIM card that is factory pre-installed on it. 12 | ©...
  • Page 13: Ordering Information

    Part Numbers CS500 IoT Gateway and Antenna Kit 11247193 Replacement CS500 IoT Gateway 11247192 Replacement Antenna 11247194 DEUTSCH mating connector bag assembly 10102025 (16 to 20 AWG) 10100944 (20 to 24 AWG) © Danfoss | October 2021 BC397226723595en-000101en-000101 | 13...
  • Page 14: Device Functions

    Service Tool functionalities may be executed remotely with the CS500. GNSS (Global Navigation Satellite System) The GNSS enables the devices to determine their position using the Global Positioning System (GPS). The position data can then be transmitted via the cellular connection to the Danfoss PLUS+1 ® Connect portalor make it available to the connected CAN bus system..
  • Page 15: Can Interfaces

    PLUS+1 ® GUIDE to monitor the machine state, performance, and position. Both position and machine data are periodically transmitted and stored to the Danfoss Data Portal. CS500 firmware update ® A firmware update to the CS500 can be loaded via the Danfoss PLUS+1 Connect portal.
  • Page 16: Connector

    DIN / Sensor Power CAN 2 High CAN bus 2 CAN 2 Low CAN bus 2 MFIO1 Multifunction Input / Output MFIO2 Multifunction Input / Output MFIN1 Multifunction Input MFIN2 Multifunction Input 16 | © Danfoss | October 2021 BC397226723595en-000101en-000101...
  • Page 17: Cs500 Technical Data

    3G – EGPRS Bands GPS, GLONASS, BeiDou, Galileo GNSS Constellations Cellular (External) and GNSS (External) Antennas Factory Installed SIM Card FCC, CE, E-Mark, PTCRB, IC, RCM Certifications IEC 60068-2-64 Vibrations IEC 60068-2-27 test Ea Shock © Danfoss | October 2021 BC397226723595en-000101en-000101 | 17...
  • Page 18: Multifunction Inputs

    Input impedance kΩ 109.1 109.3 109.5 No pull up or pull down Input impedance (5V/GND) kΩ 13.2 13.4 Pull up or pull down Input impedance (2.5V) kΩ Pull up and pull down 18 | © Danfoss | October 2021 BC397226723595en-000101en-000101...
  • Page 19: Outputs

    1.33 Input impedance to 5V Outputs Digital output Description Unit Minimum Maximum Comment Output Voltage range Current 3000 Do not connect a digital output to battery+ (back drive) without a series diode. © Danfoss | October 2021 BC397226723595en-000101en-000101 | 19...
  • Page 20: Plus+1 ® Connect Portal

    1 Hz – Operation error • 2 Hz – Configuration error • 4 Hz – CAN Fault If contacting the helpdesk or your CS PAE, EID number is required in order to receive assistance. 20 | © Danfoss | October 2021 BC397226723595en-000101en-000101...
  • Page 21: Packaging And Transport

    Do not store and/or transport the device unless it is kept at a temperature between -40 °C and +85 °C (-40 °F and +185 °F). Disposal Observe national regulations when disposing the device, accessories and its package. © Danfoss | October 2021 BC397226723595en-000101en-000101 | 21...
  • Page 22: Cs500 Technical Drawings

    Technical Information PLUS+1® Connect CS500 IoT Gateway CS500 Technical Drawings CS500 Dimensions 22 | © Danfoss | October 2021 BC397226723595en-000101en-000101...
  • Page 23 Recommended outer diameter (OD) Recommended torque 6.0 mm [0.25 in] 2.26 N•m [20 in•lbs] Antenna Connector(s) and nuts Recommended torque Cellular & GNSS 0.5 N•m [4.5 in•lbs] 18mm nut 2.94 N•m [26 in•lbs] © Danfoss | October 2021 BC397226723595en-000101en-000101 | 23...
  • Page 24 Phone: +86 21 2080 6201 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.

Table of Contents