Function Description - Bosch BAT 415 Original Instructions Manual

Charger for 12 volt batteries
Hide thumbs Also See for BAT 415:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
en
1� | BA� �1� | Product description
�.7

Function description

Figure 2 shows the characteristic charging curve for the
BAT 415.
In phase 1 of the charging process, the charging current
I
is approx. 15 % of the battery capacity set on the cont-
1
roller (Fig. 1, item 8). The green LED flashes rapidly.
When the battery has reached the final charge voltage
U
, the charging current I
1
1
of the battery capacity has now been reached. The
battery can be used as a starter battery. Phase 1 (main
charging) is complete when the charging current I
below approx. 1% of the battery capacity. The battery is
then approx. 97 % charged.
Characteristic charging curve
I
= 15% of Ah controller
I
1
U
Warm = 14,0V
1
U
Cold = 14,4V
1
I
= 1% of Ah controller
U
2
Phase 1
Green LED flashes rapidly
Fig. 2:
BAT 415 characteristic charging curve
|
1 689 979 943
2012-10-24
starts to fall. Around 65 %
falls
1
Phase 2
Green LED flashes slowly
In phase 2, the charging current I
set battery capacity. The green LED flashes slowly. Pha-
se 2 is time-controlled and lasts for 65 % of the main
charging time (phase 1). The charge voltage is limited to
U
. At the end of phase 2 the green LED is constantly lit.
2
Example: With a set battery capacity of 80 Ah, the char-
ging current I
is approx. 12 A and the charging current
1
I
is approx. 0.8 A.
2
In phase 3, the charging current is always activated
if the battery is below the voltage U
current remains active until the charge voltage U
reached.
U
Warm = 14,4V
2
Cold = 14,8V
U
2
Phase 3
Green LED constantly lit
is approx. 1 % of the
2
. The charging
3
is
1
U
= 12,7V
3
t