No.
Name
1)
LED
On : An error has occurred, i.e., "1" is
continuously received more than specified
times, or the received data length is too
short.
AB.IF
<Cause> The timing when the station that
sends data to the corresponding station is
disconnected, H/W failure, cable failure,
noise, etc.
Off : Normal
On : When the baton has not been passed to the
host station within the monitor time.
TIME
<Cause> Short monitor time, cable failure,
noise, etc.
Off : Normal
On : An error has occurred, i.e., an error code is
received.
DATA
<Cause> Cable failure, noise, etc.
Off : Normal
On : An error has occurred, i.e., the internal
processing of the data to be sent is not
UNDER
executed at constant intervals.
<Cause> H/W failure.
Off : Normal
On : An error has occurred in forward loop/
reverse loop.
<Cause> The adjacent station power is off,
LOOP
cable is disconnected/unconnected.
(Specific to A9GT-QJ71LP23)
Off : Normal
SD
Barely on : Data transmitting
RD
Barely on : Data transmitting