328XD CONFIGURATION
Wordclock
To configure the 328XD as the wordclock master, enter the 328XD Menu pages by pressing the <MENU>
button on the right hand side of the LCD display. Using the PARAM encoder beneath the display, scroll up or
down until the 'Clock Source Sel' menu is highlighted, and press <ENTER>. Here, either the internal
44.1kHz clock or the internal 48kHz clock must be selected, depending on the sampling rate at which work
is to be done. Press <ENTER> to set the sample rate and <MENU> to return to the menu pages.

Tape Ports

To ensure that the 328XD Tape Ports are set to ADAT to work with the MOTU 2408 mkII, enter the
328XD Menu pages by pressing the <MENU> button on the right hand side of the LCD display. Using the
PARAM encoder beneath the display, scroll up or down until the 'Tape Port Select' menu is highlighted.
Press <ENTER> and keep pressing the Up cursor arrow until the '<Tape Ch17-24 >' menu page is
displayed. Using the encoder set the Bank Source to ADAT.
Press the Down cursor arrow once, to set the wordlength. The MOTU 2408 mkII is capable of 24-bit
recording, and so for optimum results, 24-bit wordlength can be selected here. If your audio sequencer
software does not allow 24-bit recording, 20-bit or 16-bit should be selected. The sequencer manuals
should be consulted for further information.
Set the desired wordlength on the 328XD with the PARAM encoder.
Press the <MENU> button to return to the main menu.