Format error 5.3. Display error indication 6. Overview on commands 7. Technical data 7.1. Dimensions 8. Part number Baumer IVO GmbH & Co. KG 12.10 171.02.314/5 • Dauchinger Strasse 58-62 DE-78056 Villingen-Schwenningen Subject to modification • Phone +49 (0)7720 942-0 Fax +49 (0)7720 942-900 in technic and design.
Maintenance/repairs Always disconnect the power supply of all appliances involved. Maintenance and repair work must only be car- ried out by suitably trained experts. If troubleshooting is unsuccessful, do not continue using the device but contact the manufacturer. www.baumer.com...
Firstly all Multicon AccuDrive devices are enabled for positioning by broadcast command, the order of alignment is up to the operator .As soon as each SPA of group 1 is „in position“, the master will proceed with the next group in direct mode. www.baumer.com...
0,1 ms within the range of 0,1 ... 60 ms. Refer to command „x“ (78h). Checksum: Yes (CRC) Timeout reply*: 0,1...60 ms ** The BUS switching time is the time the SPA requires to be ready again for transmission receipt after having replied to host. BUS switching time**: <0,1 ms www.baumer.com...
Some specific commands are designated so-called broadcast commands. As soon as the master broadcasts a command to identifier 99, the command is addressed to every multicon device in the network. Each individual SPA will accomplish the respective command but will not respond any confirmation to master. www.baumer.com...
Response if actual value is outside the tolerances: Status Profile no. = 05 EOT Response Following values relating to status are possible: Status Significance o (6Fh) Actual value = target x (78h) Actual value ≠ target e (65h) SPA error www.baumer.com...
Page 8
Example 3: start enable for all motors by broadcast command (identifier=99) in group 2 SOH Adr Cmd Stat. EOT CRC Transmission Response not confirmed Example 4: abort start enable for all motors by broadcast command (identifier=99) (stop command) SOH Adr Cmd Stat. EOT CRC Transmission Response not confirmed www.baumer.com...
Page 10
Please consider that with anterior or other multicon devices command „SP“ maybe is not available. Example 4: As in example 3 but utilizing command „SP“ SOH Adr Cmd Sub Profile no.=17 Target = -12.50 EOT CRC Transmission 2Dh 30h SOH Adr Cmd Sub Profile no.=17 Target = -12.50 EOT CRC Response 2Dh 30h www.baumer.com...
Page 11
This command is utilized to read the number of the presently active profile respectively for profile alteration. Example 1: Read active profile (active profile number = 38) Transmission Cmd Profile no. = 38 EOT Response Response after reset upon having cleared all profiles: Cmd Profile no. = FF EOT Response www.baumer.com...
Page 12
EOT CRC Transmission SOH Adr Cmd Preset value = 17.25 EOT CRC Response Example 3: Set actual value as preset at all SPAs by broadcast command SOH Adr Cmd Preset value = 17.25 EOT CRC Transmission Response Not confirmed www.baumer.com...
(67h) Parameter: limit positions MIN, MAX h (68h) Parameter: Motor speed switching points i (69h) Parameter: mm / inch j (69h) Parameter: timeout window bus error k (6Bh) Parameter: motor system times m (6Dh) Read / write general parameters www.baumer.com...
Page 14
Example 1: read bit parameter (data1 to data3 = 80h; data4 to data5 = 30h) Transmission Data1 Data2 Data3 Data4 Data5 it parameter default Response Example 2: write bit parameter (positioning direction = down; turn display = On) Data1 Data2 Data3 Data4 Data5 Transmission Data1 Data2 Data3 Data4 Data5 Response www.baumer.com...
Page 15
(so-called dimension). Refer also to N 242 user manual. Utilized with other controls (PLC or PC) this parameter may be assigned to general identifications. 0 = Off Device not indicated in N 242 master 1 = On Device indicated in N 242 master. Direct target input possible www.baumer.com...
Page 16
SPAs with the corresponding resolution. Resolution 1/100 mm resp. 1/1000 inch visualized in display: 000.00 mm resp. 00.000 inch Resolution 1/10 mm resp. 1/100 inch visualized in display: 0000.0 mm resp. 000.00 inch www.baumer.com...
Tolerance is approx. 8 ms. 4.4. Identifier (address) commands Command Data amount read write Broad- Saved in Significance code in bytes cast EEPROM A (41h) Assign or indicate device identifier B (42h) SPA feedback in addressing mode www.baumer.com...
Page 22
“R” (read actual value). The R-command with the corresponding identifier is transmit- ted to the SPA. If the addressed SPA confirms that the assignment was successful, the master can proceed with next identifier. Regarding other commands the display of the respective SPA switches to standard opera- tion. www.baumer.com...
This command is utilized to read version number, device type or serial number. The following sub-commands are available: Data = V (56h) = read version Data = T (54h) = read device type Data = S (53h) = read serial number www.baumer.com...
The target transmitted resp. DIM value is exceeding the MAX limit. Note: Take loops into consideration. Troubleshooting: Transmit new admissible position value. Target transmitted respectively DIM parameter is below the MIN limit. Note: Take loops into consideration.. Troubleshooting: Transmit new admissible position value. www.baumer.com...
Specific command: Profile reset (clear) Q (51h) Specific command: SPA reset R (52h) Read current value S (53h) Read / write target U (55h) Offset V (56h) Read / write profile number X (58h) Specific command: read version number Z (5Ah) Set preset www.baumer.com...
User surface / keypad Keypad with two softkey Housing With hollow shaft for direct shaft mount Dimensions W x H x L 37 x 75 x 45 mm Mounting Hollow shaft mount Weight approx. 120 g Material Polyamide black, UL 94V-0 www.baumer.com...