Installation
Vienna II is designed for reliability, high performance and built to the highest
standards. Whilst great care has been taken to ensure that installations are made as
trouble-free as possible, care taken at this stage, followed by correct setting up will
be rewarded by a long life and reliable operation.
Warning!
Before switching on your Vienna II console, check that the mains
voltage selectors on the power supply units are set to the correct
mains voltage for your area, and that the fuses are of the correct
rating. This is clearly marked on the case of the power supplies. Do
not replace the fuses with any other type, as this could become a
safety hazard and will void the warranty.
Always ensure that you use the correct power supplies for your console. The
Vienna II console requires a CPS900 power supply.
Wiring Considerations
A
For optimum performance it is essential for the earthing system to be clean and
noise-free, as all signals are referenced to this earth. A central point should be
decided on for the main earth point, and all earths should be 'star-fed' from this
point. It is recommended that an individual earth wire be run from each electrical
outlet, back to the system star point to provide a safety earth reference for each piece
of equipment.
6
B Install separate mains outlets for the audio equipment, and feed these
independently from any other equipment.
C
Avoid locating mains distribution boxes near audio equipment, especially tape
recorders, which are very sensitive to electro- magnetic fields.
D Where possible ensure that all audio cable screens and signal earths are
connected to ground only at their source.