Calibration factors
▷ The Elster internal metrological "Q" data are dis-
▷
played.
Calibration factors
Q : 0.000m
3
Q : 6.000m
3
Q : 12.000m
Tc : Elektronic
Tb : 15°C
▷ Temperature conversion Tc (OFF/mechanical/
▷
electronic), reference temperature Tb.
–
Tc: OFF (no temperature conversion)
or
–
Tc: Mechanical
Tb: 15°C (reference temperature)
or
–
Tc: Electronic
Tb: 15°C (reference temperature)
Establishing an optical
communication link
▷ In order to configure the electronic index for the
▷
respective application, the optical communication
link must be activated.
1 Position the opto-adapter head on the interface
provided.
5 6 7 8
1 2 3 4
2 Press any user key.
▷ Optical communication is enabled for 1 min.
▷
▷ If the optical communication link is not used dur-
▷
ing this time, the interface will be deactivated.
Initiate communication.
▷ The procedure depends on your user software.
▷
/h → 16384
/h → 16384
/h → 17203
3
Changing the battery
▷ The battery is available as a spare part. Please
▷
contact the manufacturer, see [Contact – p. 8].
1 Prepare the index for changing the battery.
5 6 7 8
B K -G x
1 2 3 4
▷ The battery can only be replaced when the optical
▷
communication link has been established, see
[Establishing an optical communication link – p. 6].
Otherwise data will be lost.
2 Initiate changing the battery.
▷ The procedure depends on your user software.
▷
▷ Attention! The battery may only be removed once
▷
a release message has been issued by the index.
▷ As soon as the release message "NOW READY
▷
TO CHANGE THE BATTERY PACK" appears,
there is a 4-minute time period to remove the
battery. If the battery is not removed from the con-
tacts within this timeframe, the index will restart.
▷ If the battery is not removed from the contacts
▷
within the time provided, repeat the steps as of
point 2 .
Replace the battery.
B K -G x
1 2
▷ As soon as the new battery has been pushed
▷
into the electronic index and onto the contacts,
the index starts and is in operation again after a
short time.
▷ The basic display appears.
▷
▷ Optical communication is enabled for 1 min. If the
▷
optical communication link is not used during this
time, the interface will be deactivated.
4 Reprogram the battery parameters.
▷ The procedure depends on your user software.
▷
Electronic index without communication module:
▷ After the battery has been replaced, check the
▷
time and update it if necessary. Note the global
UTC format.
5 Re-seal the service seal.
GB-6
B K -G x
1 2 3
5 6 7 8
B K -G x
1 2 3 4