Service Mode; Activating Service Mode; Service Mode Menu Overview - Elster BK Series Operating Instructions For Operators And Installers

Table of Contents

Advertisement

Service mode

▷ In Service mode, meter-specific operating data
can be called up.

Activating Service mode

1 Hold the selection key
▷ A pixel will appear in each corner of the display.
2 Observe one pixel:
While the pixel is visible, hold the selection key
pressed down and release the key as soon
as the pixel has disappeared.
 Repeat the process, until all the pixels are off and
"Test instructions" appears in the menu area.
▷ Service mode is activated.

Service mode menu overview

Test instructions
Temperature
LCD pixel test
Test pixel screen
Cyclic test
UMI peripherals
UMI-1
UMI-2
UMI-3
Calibration factors
Test instructions
Test instructions
Automatic return to main
menu after 5minutes of
inactivity
Hold
on any screen to
return immediatelv
Temperature
▷ The current gas temperature is displayed.
Temperature
24.39°C
pressed down.
GB-5
LCD pixel test
▷ A display test can be carried out in this menu.
1 Follow the displayed instructions.
▷ A test pattern is shown in the display.
2 Briefly press the selection key
▷ A further test pattern appears in the display.
 Hold the selection key pressed down. The display
switches to the previous menu.
Cyclic test
▷ The accuracy of the meter can be checked using
a cyclic volume test.
Cyclic test: Starting
C: 00.000000
U: 00.000000
Cycles: 0-0 0000.00
Press
to abandon test
C = volume,
U = volume (temperature converted),
Cycles = number of complete measuring
cycles (measuring unit rotations) – number of
intermediate sampling points in the measuring
cycle.
Overall measuring time [s].
▷ Measurement must be carried out with a constant
flow rate in order to ensure that the cyclic test
produces an accurate result.
1 Briefly press the selection key
the measurement. A beep confirms the start of
the measurement.
▷ In order to pause the measurement, briefly press
the selection key
when the full number of measuring unit rotations
has been completed.
▷ Measurement ends automatically after 90 min.
▷ A beep indicates that measurement has ended.
2 Read off the measurement results.
UMI peripherals
▷ The status of the available interfaces for optional
communication modules is displayed.
.
m
3
m
3
in order to start
again. Measurement stops

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bk-g seriesBk-g1.6Bk-g25Bk-g1.6tBk-g25t

Table of Contents