Installation; Technical Data; Heating Elements Rating; Electrical Connection - Zanussi ZBP 1165 Instruction Booklet

Zanussi instruction built-in oven zbp 1165
Table of Contents

Advertisement

Installation

The oven must be installed according to the
instructions supplied.

Technical Data

Dimensions of recess
Height
undertop: 593 mm; in column 580 mm
Width
Depth
Dimensions of the oven cavity
Height
Width
Depth
Oven capacity

Electrical Connection

The oven is designed to be connected to 230 V (50 Hz)
electricity supply.
The oven has an easily accessible terminal block which
is marked as follows:
Letter L
-
Live terminal
Letter N
-
Neutral terminal
or E
-
Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given below.
For Uk use only
Connection
Min. size
via
Cable/flex
• 13 A socket 2.5 mm
outlet
• 13 A
spur box
• Cooker
2.5 mm
Control
Circuit
For Europe use only
Min. size Cable/flex
1.5 mm
2
30
560 mm
550 mm
335 mm
395 mm
400 mm
53 litres
Cable / flex Fuse
type
3 core
13 A
2
butyl
min.
insulated
PVC/PVC
15 A min.
2
twin and
20 A max.
earth
Cable / flex type
Fuse
H07 RN-F, H05 RN-F, 13 A
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F
This oven must be installed by qualified
personnel to the relevant British Standards.

Heating elements rating

Oven element
Top element
Bottom element
Convection element
Grill element
Double Grill element
Pizza Oven Function
Convection Fan
Oven Light
Cooling Fan
Total Rating
Supply voltage (50 Hz)
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains), with
a minimum gap of 3mm between the switch contacts and
of a type suitable for the required load in compliance with
the current rules.
The switch must not break the yellow and green earth
cable at any point.
The yellow and green earth cable should be 2-3 cm. longer
than the other cables.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a temperature
of more than 50°C above the ambient temperature.
Before the oven is connected, check that the main fuse
and the domestic installation can support the load; and
that the power supply is properly earthed.
The manufacturer disclaims any responsibility should
these safety measures not be carried out.
1,800 W
800 W
1,000 W
2,000 W
1,650 W
2,450 W
2,000 W
25 W
40 W
25 W
2,500 W
230 V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents