Shrm-I - Toshiba RBC-EXW21E2 Quick Reference

Super digital inverter remote controller
Table of Contents

Advertisement

SHRM-i

DN
Item
Filter display delay timer
01
Dirty state of filter
02
Central control address
03
Specific indoor unit
04
priority
Heating temp shift
06
Existence of [AUTO]
0d
mode
FS unit
0E
Connection set of multiple
indoor units
Cooling only
0F
Type
10
Indoor unit capacity
11
12 Line address
13 Indoor unit address
Group address
14
Group address
19
Temp difference of
[AUTO] mode selection
1E
COOL → HEAT,
HEAT → COOL
Automatic restart of
28
power failure
Selection of option/error
2A
input (CN70)
HA terminal (CN61)
2E
select
31 Ventilating fan control
32 TA sensor selection
33 Temperature unit select
Swing mode
F0
Louver fixed position
F1
(Louver No.1)
Louver fixed position
F2
(Louver No.2)
Louver fixed position
F3
(Louver No.3)
Louver fixed position
F4
(Louver No.4)
0000: None
0002: 2500H
0004: 10000H
0000: Standard
0001: High degree of dirt (Half of standard time)
0001: No.1 unit
to
0099: Unfixed
0000: No priority
0000: No shift
0002: +2 C
to
0000: Provided
0001: Not provided (Automatic selection from connected outdoor unit)
0000: Standard (1 FS unit : 1 indoor unit)
0001: Multiple units connected ((1 FS unit : Multiple indoor units)
0000: Heat pump
0001: Cooling only (No display of [AUTO] [HEAT])
0001: 4-way Cassette
0000: Unfixed
0001: No.1 unit
to
0001: No.1 unit
to
0000: Individual
0002: Follower unit of group
0000: No louver
0002: (1-way Cassette type, Ceiling type)
0003: (2-way Cassette type)
0004: (4-way Cassette type)
0000: 0 deg
to
(For setup temperature, reversal of COOL/HEAT by } (Data value)/2)
0000: None
0000: Filter input
0002: None
0000: Usual
0002: Fire alarm input
0000: Unavailable
0000: Body TA sensor
0000: C (at factory shipment)
0001: Standard
0003: Cycle swing
0000: Release
0005: Downward discharge position
0000: Release
0005: Downward discharge position
0000: Release
0005: Downward discharge position
0000: Release
0005: Downward discharge position
Description
0001: 150H
0003: 5000H
0064: No.64 unit
0001: Priority
0001: +1 C
0010: +10 C
(Up to +6 recommended)
0001 to 0050
0030: No.30 unit
0048: No.48 unit
0001: Header unit of group
0001: Swing only
0010: 10 deg
0001: Restart
0001: Alarm input (Air washer, etc.)
0001: Leaving-ON prevention control
0001: Available
0001: Remote controller sensor
0001: F
0002: Dual swing
0001: Horizontal discharge position
0001: Horizontal discharge position
0001: Horizontal discharge position
0001: Horizontal discharge position
– 40 –
At shipment
According to type
0000: Standard
0099: Unfixed
0000: No priority
0002: +2 C
(Floor type 0000: 0 C)
0001: Not provided
0000:Standard
0000: Heat pump
Depending on model
type
According to capacity
type
0099: Unfixed
0099: Unfixed
0099: Unfixed
According to type
0003: 3 deg
(Ts ±1.5)
0000: None
0002: None
0000: Usual
(HA terminal)
0000: Unavailable
0000: Body TA sensor
0000: C
0001: Standard
0000: Not fixed
0000: Not fixed
0000: Not fixed
0000: Not fixed