MCAC-UTSM-201503
Parallel connect the front with rear sides
>3000
3.2 Moving and installation
Since the gravity center of the unit is not at its physical center, so please be careful when lifting it with
a sling.
Never hold the inlet of the outdoor unit to prevent it from deforming.
Do not touch the fan with hands or other objects.
Do not lean it more than 45° , and do not lay it sidelong.
Make concrete foundation according to the sepecifications of the outdoor units.(refer to Fig.4-6)
Fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthquake or
strong wind.
3.3 Centralized chassis drainage
When the outdoor unit requires centralized drainage, install the chassis and two waterproof covers for the
chassis. Install the water outlet union pipe and sealing ring onthe chassis, and then connect the drainage
R410A Full DC Inverter Split Duct Type Technical Manual
>6000
>1000
Fix with bolt
>4000
>300
(Unit:mm)