Dometic 10 Series Installation Manual page 19

Absorber refrigerator
Hide thumbs Also See for 10 Series:
Table of Contents

Advertisement

Available languages

Available languages

RMD10
4.3
Making air inlet and outlet vents
I
NOTE
• Deviations from the inlet and outlet variations shown here must be
approved by the manufacturer.
• At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been pro-
vided.
➤ Make an air inlet vent and an air outlet vent in the outer wall with the size of
249 mm x 490 mm (9.8 in. x 19.29 in.).
When doing so, observe the information, see chapter "Preparing the installa-
tion" on page 16.
If the ventilation grill of the air inlet vent cannot be installed flush with the floor of the
niche, install an inlet vent in the floor. Any leaking gas can thus flow downwards.
➤ Make an air inlet vent of at least Ø 40 mm (1.57 in.) in the floor (fig. 8 1, page 7)
behind the refrigerator near the gas burner.
➤ Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig. 8 2, page 7).
If you have to use a roof vent instead of the air outlet vent:
➤ Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions.
When doing so, observe the information in chapter "Preparing the installation"
on page 16.
4.4
Installing the ventilation grill
I
NOTE
Use exclusively original Dometic ventilation grills to ensure safe
operation.
No. in
fig. 9, page 7
1
2
EN
Description
Slider
Ventilation grill
Installing the refrigerator
19