INSTALLATION

INSPECTION

Do not throw away
packaging if damage is
evident!

UNPACKING

PLUMBING

The plumber must flush
the incoming water line!
WATER SUPPLY
CONNECTIONS:
WATER HARDNESS
HIGHER THAN 3 GPG
A water hardness test
must be performed.
07610-004-54-86-D
Before installing the machine, check packaging and machine for damage. Damaged
packaging might be an indication of damage to the machine. If there is any type of
damage to both packaging and unit, do not throw away the packaging. The machine
has been inspected at the factory before shipping and is expected to arrive in new,
undamaged condition. However, rough handling by carriers or others might result in
damage to the machine while in transit. If this occurs, do not return the machine to
the manufacturer. Instead, contact the carrier and ask them to send a representative
to the site to inspect the damage and request that an inspection report be completed.
Contact the carrier within 48 hours of receiving the machine as well as the dealer that
sold you the machine.
The machine should be unpacked and removed from the pallet before installing. Open
the front door and remove all materials from inside. Once unpacked, verify there are no
missing parts. If a part is missing, contact the manufacturer immediately.
All plumbing connections must be made to adhere to local, state, territorial, and
national codes. The installing plumber is responsible for ensuring the incoming
water lines are flushed of debris before connecting to the machine. Note that chips
and materials from cutting processes can become lodged in the solenoid valves
and prevent them from opening or closing. Any valves that are found to be fouled
or defective because of foreign matter left in the water line, and any subsequent
damage, are not the responsibility of the manufacturer.
See the Dimensions page and reference item "B" for water inlet connection location.
The manufacturer does NOT endorse "Tankless On-demand" water heaters
NOTICE
for use with their dishmachines. The manufacturer DOES endorse, and highly
recommends, the standard "Tank" style water heaters, sized to properly handle the
water heating requirements of the facility.
A hardness test kit can be found on the warning tag attached to the incoming plumbing
connection on the back of the machine. If water hardness is higher than 3 GPG and a
water softener is not being used, install the optional Scale Prevention System (SPS)
into the water line between the facility water line and the machine water line (installed
at the factory). See the Scale Prevention System page for more information on the
SPS. Observe proper inlet/outlet water directions. A water shut-off valve should be
installed before installing the SPS to allow access for service. The water supply must
be capable of a minimum of 10 PSI "flow" pressure at the recommended temperature
indicated on the data plate.
Example
*
Facility
Shut-off
Adapter
SPS
Water Line
Valve

INSTRUCTIONS

*
Adapter
Machine
Water Line
*Adapters needed will vary.