6 System parameters

6.5.2 Output Size

6.5.2 Output Size
Parent
Output Size belongs to the type PROFINET Internal Device, in the topic I/O System.
Cfg name
OutputSize
Description
The parameter Output Size is used to configure the output slot configuration of
the PROFINET internal device.
Usage
The parameter Output Size is only valid for the PN_Internal_Device. It will configure
the output slot size for the PROFINET internal device. This size must match the
connecting PLC's or other PROFINET controller's defined input slot size. For more
information, see
Prerequisites
The option PROFINET Controller/Device or PROFINET Device must be installed.
Default value
The default value is 64 bytes (512 signal bits).
Allowed values
8, 16, 32, 64, 128 or 256 bytes (64, 128, 512, 1024 or 2048 signal bits).
68
Input and output size on page
© Copyright 2015-2018 ABB. All rights reserved.
30.
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G