Output Offset On Destination Device - ABB IRC5 Applications Manual

Profinet controller/device
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

6 System parameters

6.4.2 Output Offset on Destination Device

PROFINET Controller/Device
6.4.2 Output Offset on Destination Device
Parent
Output Offset On Destination Device belongs to the type Signal, in the topic I/O
System.
Cfg name
TransferOutputOffset
Description
The parameter Output Offset On Destination Device specifies the output start bit
on the PROFINET internal device set by the transfer signal.
Prerequisites
The option PROFINET Controller/Device must be installed.
Limitations
The destination I/O device can only be the PROFINET internal device.
Default value
The default value is -1. This means that no Output Offset On Destination Device
is defined.
Allowed values
The values are in the range of -1 to 65535.
Additional information
The parameter Output Offset On Destination Device specifies the start bit on the
internal device. And, for bits specified in a group are transferred starting with the
first bit.
64
© Copyright 2015-2018 ABB. All rights reserved.
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G