CHAPTER 9

Cabinet Requirements

SRX650 Services Gateway Cabinet Size and Clearance Requirements

Related
Documentation
Copyright © 2018, Juniper Networks, Inc.
SRX650 Services Gateway Cabinet Size and Clearance Requirements on page 51
SRX650 Services Gateway Cabinet Airflow Requirements on page 52
You can install the SRX650 Services Gateway in a 19 in (48.3 cm) cabinet as defined in
Cabinets, Racks, Panels, and Associated Equipment (document number EIA-310-D)
published by the Electronic Industries Alliance (
You must mount the services gateway horizontally in the cabinet.
NOTE:
The holes in the mounting brackets chassis are spaced 1.25 in (3.2
cm) apart, measured from the center of the hole.
When selecting a cabinet, ensure that it meets the following specifications:
The cabinet is at least 2U (3.50 in or 8.89 cm) and can accommodate the services

gateway.

The outer edges of the mounting brackets extend the width of either chassis to 19 in
(48.2 cm), and the front of the chassis extends approximately 0.5 in (1.27 cm) beyond
the mounting brackets.
The minimum total clearance inside the cabinet is 30.7 in (78 cm) between the inside
of the front door and the inside of the rear door.
NOTE:
A cabinet larger than the minimum required provides better airflow
and reduces the chance of overheating.
SRX650 Services Gateway Chassis on page 17
SRX650 Services Gateway Cabinet Airflow Requirements on page 52
SRX650 Services Gateway Spacing of Mounting Bracket and Flange Holes on page 47
SRX650 Services Gateway Rack Size and Strength Requirements on page 47