Download Print this page

Canon Business Inkjet WG7450Z Getting Started page 46

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Network & Remote Monitoring Service Connection
Connecting to a Remote Monitoring Service
Setting The Date/Time & Firmware Update
EN
Error code
8000 2028
8000 2029
8000 2046
Carrying out a communication test
Error code
0000 0003
8000 0101
8000 0207
8000 0208
8000 2000
8000 0304
8000 2004
8000 2047
8000 2003
44
Cause
Server certificate error:
• Date/time on the device are not correct
• Root certificate to server is not registered in
the device
• The user is using a different certificate, and the
official certificate file is not registered
Server certificate URL check error
Server certificate expired:
• Date in device is past expiry on certificate
• Root certificate registered in the device is
expired
• The root certificate first registered by the user
is being used, and the official certificate file is
not registered
Cause
No schedule/communication test not
completed
Remote monitoring server reply error
Internal schedule invalid
Other communication error
Signal consumption error during
communication test
Succeeded in communicating with the remote
monitoring server, but an error occurred
Reply from remote monitoring server timed out
Communication test was run while network
connection was still not ready immediately after
turning the device's main power off/on
For details
"Setting the Date/Time", "Updating the Firmware" in the Online Manual
Set the accurate date/time in the device.
If the date/time in the device were correct,
update to the latest firmware.
Run and complete the communication test.
Wait and run the communication test again.
After turning the device on, wait about 60
seconds before running the communication test.
Solution
Solution