3) Room temperature control for indoor unit sensor
Refer to Function 95, before performing this setting.
Depending on the installed environment, correction of the room temperature sensor may be
required.
Select the appropriate control setting according to the installed environment.
The temperature correction values show the difference from the Standard setting "00"
(manufacturer's recommended value).
*When Function 95-01(High insulation) is set, the Standard setting "00" will be the same as No
correction "01" [0.0°F (0.0°C)].
Function number
30
31
(For cooling)
(For heating)
In case of Slim duct type and Floor/Ceiling type models:
In floor console installations, select "01".
4) Auto restart
Enable or disable automatic restart after a power interruption.
Function number
40
*Auto restart is an emergency function such as for power outage etc.
Do not attempt to use this function in normal operation.
Be sure to operate the unit by remote controller or external device.
5) Room temperature sensor switching
(Only for wired remote controller)
When using the Wired remote controller temperture sensor, change the setting to "Both" (01).
Function number
42
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller are active.
*Remote controller sensor must be turned on by using the remote controller.
Setting value
Setting description
00
Standard setting*
01
No correction 0.0°F 0.0°C
02
-1°F (-0.5°C)
03
-2°F (-1.0°C)
04
-3°F (-1.5°C)
05
-4°F (-2.0°C)
06
-5°F (-2.5°C)
07
-6°F (-3.0°C)
08
-7°F (-3.5°C)
09
-8°F (-4.0°C)
10
+1°F (+0.5°C)
11
+2°F (+1.0°C)
12
+3°F (+1.5°C)
13
+4°F (+2.0°C)
14
+5°F (+2.5°C)
15
+6°F (+3.0°C)
16
+7°F (+3.5°C)
17
+8°F (+4.0°C)
Setting value
Setting description
00
01
Setting value
Setting description
00
Indoor unit
01
- (01 - 38) -
(  . . .Factory setting)
More cooling
Less heating
Less cooling
More heating
(  ... Factory setting)
Enable
Disable
(  ... Factory setting)
Both