Summary of Contents for Rheem RIWH09AVFJ

  • Page 1 R410A REFRIGERANT INVERTER AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR RIWH09AVFJ RIWH12AVFJ OUTDOOR ROSH09AFWJ ROSH12AFWJ...
  • Page 2: Indoor Unit

    1. INDOOR UNIT WALL MOUNTED TYPE : RIWH09AVFJ RIWH12AVFJ DTR_AS129E_01 2017.01.27...
  • Page 3: Table Of Contents

    CONTENTS 1. INDOOR UNIT 1. SPECIFICATIONS ....................01-01 2. DIMENSIONS ......................01-02 3. WIRING DIAGRAMS ..................01-04 4. CAPACITY TABLE ....................01-05 4-1. COOLING CAPACITY ..................01-05 4-2. HEATING CAPACITY ..................01-07 5. FAN PERFORMANCE ..................01-08 5-1. AIR VELOCITY DISTRIBUTION ...............
  • Page 4: Specifications

    1. SPECIFICATIONS WALL MOUNTED Type INVERTER HEAT PUMP Model name RIWH09AVFJ RIWH12AVFJ Power source 208/230V~60HZ Available voltage range 187-253V~60HZ 2.637 3.516 Rated BTU/h 9000 12000 Cooling 0.50-3.20 0.90-3.90 Min-Max BTU/h 1700-10900 3100-13300 Capacity 3.516 4.689 Rated BTU/h 12000 16000 Heating 0.50-4.40...
  • Page 5: Dimensions

    2. DIMENSIONS „ MODELS :RIWH09AVFJ, RIWH12AVFJ „ Unit: in (mm) 8-1/16 (204) 34-1/4 (870) [34-1/4 (870)] 16-3/4 (426) 17-1/2 (444) 12-3/16 (310) 11-5/8 (295) Outline of unit 6-1/2 (165) 5-11/16 (144) 2-9/16 (65) 2-9/16 (65) for pipe inlet for pipe inlet...
  • Page 6 „ INSTALLATION PLACE „ Unit: in (mm) Outline of unit 1 (25) or more 3 (52) or more 4 (86) or more 6 (144) or more 60 (1,500) or more - (01-03) -...
  • Page 7: Wiring Diagrams

    3. WIRING DIAGRAMS „ MODELS :RIWH09AVFJ, RIWH12AVFJ „ - (01-04) -...
  • Page 8: Capacity Table

    4. CAPACITY TABLE 4-1. COOLING CAPACITY „ MODEL : RIWH09AVFJ „ Indoor temperature °FDB °FWB °FDB 8.34 5.55 0.22 9.30 6.19 0.22 10.26 6.82 0.23 10.57 7.04 0.22 11.21 7.46 0.22 11.85 7.89 0.23 7.95 5.29 0.24 8.86 5.90 0.24 9.78...
  • Page 9 „ MODEL : RIWH12AVFJ „ Indoor temperature °FDB °FWB °FDB 11.25 7.76 0.33 12.53 8.65 0.33 13.80 9.53 0.35 14.23 9.82 0.34 15.08 10.41 0.34 15.93 11.00 0.35 10.66 7.36 0.37 11.87 8.19 0.38 13.08 9.03 0.40 13.49 9.31 0.39 14.30 9.87 0.39...
  • Page 10: Heating Capacity

    4-2. HEATING CAPACITY „ MODEL : RIWH09AVFJ „ Indoor temperature °FDB °FDB °FWB 7.18 0.68 7.01 0.69 6.84 0.71 6.66 0.72 8.13 0.73 7.94 0.75 7.74 0.76 7.55 0.78 9.10 0.76 8.88 0.78 8.66 0.79 8.45 0.81 10.48 0.81 10.23 0.83...
  • Page 11: Fan Performance

    5. FAN PERFORMANCE Conditions: Fan speed: HIGH 5-1. AIR VELOCITY DISTRIBUTION Operation mode: FAN „ MODELS :RIWH09AVFJ, RIWH12AVFJ „ (ft.) Unit : ft./s (m/s) TOP VIEW Vertical airflow direction louver: Up Horizontal airflow direction louver: Center 3 (1) 2 (0.5) 7 (2) (ft.)
  • Page 12: Air Flow

    5-2. AIR FLOW „ MODELS :RIWH09AVFJ, RIWH12AVFJ „ zCooling „ Number of Fan speed rotations Air flow (r.p.m.) HIGH 1320 1160 QUIET zHeating „ Number of Fan speed rotations Air flow (r.p.m.) HIGH 1320 1160 QUIET - (01-09) -...
  • Page 13: Operation Noise (Sound Pressure)

    6. OPERATION NOISE (SOUND PRESSURE) 6-1. NOISE LEVEL CURVE „ MODEL : RIWH09AVFJ „ zCooling „ zHeating „ NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 High High NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 Quiet NC-20...
  • Page 14: Sound Level Check Point

    6-2. SOUND LEVEL CHECK POINT 40in. (1m) - (01-11) -...
  • Page 15: Electrical Characteristics

    7. ELECTRICAL CHARACTERISTICS Model name RIWH09AVFJ RIWH12AVFJ Voltage 208 / 230 ~ Power supply Frequency Max. operating current Connection cable Wiring spec. *1 Limited wiring length ft.(m) 68 (21) 1*: Wiring specification Selected sample (Selected based on Japan Electrotechnical Standards and Codes Committee E0005)
  • Page 16: Safety Devices

    8. SAFETY DEVICES Model Protection form RIWH09AVFJ RIWH12AVFJ Circuit protection Current fuse (PC board) 250V 3.15A OFF: 221 ± 18 °F (105 ± 10 °C) Fan motor protection Thermal protector program ON: 194 ± 18 °F (90 ± 10 °C)
  • Page 17: External Input & Output

    9. EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CNA01 Control input See external CNB01 Operation status output input/output settings for details. CNB02 Error status output 9-1. EXTERNAL INPUT „ CONTROL INPUT (Operation/Stop or Forced stop) „ The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
  • Page 18 zWhen function setting is in "Forced stop" mode „ Input signal Forced stop Command Normal Operation Indoor unit Stop Remote controller Remote control operation invalidity zParts (Optional) „ Parts name Model name External connect kit RXXWZXZ5 Communication kit RXXCBXZ2 * For operating the EXTERNAL function, the wall mounted type requires the communication kit in addition to the wire (RXXWZXZ5).
  • Page 19: External Output

    9-2. EXTERNAL OUTPUT „ OPERATION STATUS OUTPUT „ An air conditioner operation status signal can be output. zCircuit diagram example „ Indoor unit control PC board Communication kit Connected unit Connector 24V DC Ex.)Relay unit Ex.)Display Relay power supply *33ft. (10m) Signal Optional parts...
  • Page 20 „ ERROR STATUS OUTPUT „ An air conditioner error status signal can be output. zCircuit diagram example „ Indoor unit control PC board Communication kit Connected unit Connector 24V DC Ex.)Relay unit Ex.)Display Relay power supply *33ft. (10m) Signal Optional parts Locally purchased *: Make the distance from the PC board to the connected unit within 33ft.
  • Page 21: Wireless Remote Controller

    10. WIRELESS REMOTE CONTROLLER „ FUNCTIONS „ Signal transmitter MODE button FAN button MIN. HEAT button ECONOMY button SWING button TEMP. button SET button POWERFUL button TIMER ON button REG1U Start/Stop button TIMER OFF button REG1U RESET button TIMER SELECT button °C / °F switching button TIMER SLEEP button CLOCK ADJUST button...
  • Page 22: Function Settings

    11. FUNCTION SETTINGS 11-1. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit to malfunction. •...
  • Page 23 „ FUNCTION DETAILS „ Functions 1) Filter sign 2) Room temperature control for indoor unit sensor 3) Auto restart 4) Room temperature sensor switching 5) Remote controller custom code 6) External input control 7) Room temperature sensor switching (Aux.) 8) Indoor unit fan control for energy saving for cooling 9) Room temperature control for wired remote controller sensor 10) Heat Insulation condition (building insulation) 1) Filter sign...
  • Page 24 3) Auto restart Enable or disable automatic restart after a power interruption. (  ... Factory setting) Function number Setting value Setting description Enable  Disable * Auto restart is an emergency function such as for power outage etc. Do not attempt to use this function in normal operation. Be sure to operate the unit by remote controller or external device.
  • Page 25 8) Indoor unit fan control for energy saving for cooling Enables or disables the power-saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation. (  ... Factory setting) Function number Setting value Setting description Disable ...
  • Page 26 „ REMOTE CONTROLLER CUSTOM CODE SETTING „ Use the following steps to select the custom code of the remote controller. (Note that the air conditioner cannot receive a signal if the air conditioner has not been set for the matching custom code.) 1.
  • Page 27: Optional Parts

    12. OPTIONAL PARTS 12-1. CONTROLLERS Exterior Parts name Model No. Summary Large and full-dot liquid crystal Monitor Mo 10:00AM screen, wide and large keys Mode Set temp. Wired remote easy to press, user-intuitive ° F Cool High RXRVNUM Icon check: Menu controller arrow key.
  • Page 28 2. OUTDOOR UNIT SINGLE TYPE : ROSH09AFWJ ROSH12AFWJ DTR_AO230E_01 2017.01.27...
  • Page 29 CONTENTS 2. OUTDOOR UNIT 1. SPECIFICATIONS ....................02 - 01 2. DIMENSIONS ......................02 - 02 3. REFRIGERANT CIRCUIT ................02 - 04 4. WIRING DIAGRAMS ..................02 - 06 5. CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE ..............
  • Page 30: Specifications

    1. SPECIFICATIONS Type INVERTER HEAT PUMP Model name ROSH09AFWJ ROSH12AFWJ Power sourse 208/230V~60HZ Available voltage range 187-253V~60HZ Starting current Cooling 995(1690) 1036(1760) Airflow rate Heating 906(1540) 889(1510) Type×Q'ty Propeller fan×1 Motor output Cooling Sound pressure level dB(A) Heating 19-13/16×25-1/4×1-7/16 19-13/16×35-1/4×1-7/16 Dimensions (H×W×D) 504×642×36.4...
  • Page 31: Dimensions

    2. DIMENSIONS „ MODEL : ROSH09AFWJ „ Unit : in.(mm) 13/16 (20) 26 (660) 2-11/16 (68) 3/8 (10) 11-7/16 (290) 11/16 (18) 13-7/8 (352) 17-7/8 (454) 5-5/16 (135) Unit : in.(mm) „ INSTALLATION PLACE „ CAUTION • When the outdoor temperature is 32 °F (0 °C ) or less, do not use the accessory drain pipe and drain cap.
  • Page 32 „ MODEL : ROSH12AFWJ „ Unit : in.(mm) 13/16 (20) 31-1/8 (790) 2-11/16 (68) 3/8 (10) 11-7/16 (290) 11/16 (18) 13-7/8 (352) 21-1/4 (540) 8-1/4 (209) Unit : in.(mm) „ INSTALLATION PLACE „ CAUTION • When the outdoor temperature is 32 °F (0 °C ) or less, do not use the accessory drain pipe and drain cap.
  • Page 33: Refrigerant Circuit

    3. REFRIGERANT CIRCUIT „ MODEL : ROSH09AFWJ „ - (02 - 04) -...
  • Page 34 „ MODEL : ROSH12AFWJ „ - (02 - 05) -...
  • Page 35: Wiring Diagrams

    4. WIRING DIAGRAMS „ MODEL : ROSH09AFWJ „ - (02 - 06) -...
  • Page 36 „ MODEL : ROSH12AFWJ „ - (02 - 07) -...
  • Page 37: Capacity Compensation Rate For Pipe Length And Height Difference

    5. CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE „ MODEL : ROSH09AFWJ „ Pipe length COOLING 7.5m 16ft. 25ft. 33ft. 49ft. 66ft. 49ft. 0.872 0.910 Ú 1 33ft. 0.961 0.886 0.925 Indoor unit is higher 7.5m 25ft. 0.979 0.965 0.890 0.929...
  • Page 38 „ MODEL : ROSH12AFWJ „ Pipe length COOLING 7.5m 16ft. 25ft. 33ft. 49ft. 66ft. 49ft. 0.858 0.868 Ú 1 33ft. 0.929 0.872 0.882 Indoor unit is higher 7.5m 25ft. 0.960 0.933 0.876 0.885 than outdoor unit. 16ft. 0.992 0.964 0.937 0.879 0.889 Height...
  • Page 39: Additional Charge Calculation

    6. ADDITIONAL CHARGE CALCULATION „ MODEL : ROSH09AFWJ „ Refrigerant type R410A lb. oz. 1lb.14oz. Refrigerant amount zREFRIGERANT CHARGE „ 49 or less 66 (MAX) Pipe length 15 or less 20 (MAX) 0.22oz./ft. (20g/m) Additional charge +100 „ MODEL : ROSH12AFWJ „...
  • Page 40: Air Flow

    7. AIR FLOW „ MODEL : ROSH09AFWJ „ zCooling „ Number of rotations Air flow (r.p.m.) 1690 zHeating „ Number of rotations Air flow (r.p.m.) 1540 „ MODEL : ROSH12AFWJ „ zCooling „ Number of rotations Air flow (r.p.m.) 1760 1036 zHeating „...
  • Page 41: Operation Noise

    8. OPERATION NOISE 8-1. NOISE LEVEL CURVE (SOUND PRESSURE) „ MODEL : ROSH09AFWJ „ zCooling zHeating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000...
  • Page 42: Sound Level Check Point

    8-2. SOUND LEVEL CHECK POINT 40 in. (1m) - (02 - 13) -...
  • Page 43: Electric Characteristics

    9. ELECTRIC CHARACTERISTICS Model Name ROSH09AFWJ ROSH12AFWJ Voltage 208 / 230~ Power Supply Frequency Starting Current MAX. CKT. BKR *1) Wiring Spec. Power Cable *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E00005) MCA: Min Circuit Amp(Calculation based on UL1995) MAX.
  • Page 44: Safety Devices

    10. SAFETY DEVICES Model Protection form ROSH09AFWJ ROSH12AFWJ Current fuse 250V 20A (IN THE INVERTER CASE) 250V 5A Circuit protection Current fuse 250V 15A (MAIN PRINTED ─ 250V 3.15A CIRCUIT BOARD) OFF: 212±27°F (100±15°C) OFF: 302±27°F (150±15°C) Fan motor protection Terminal protection program ON: 203±18°F (95±10°C) ON: 230±18°F (120±15°C)

This manual is also suitable for: