FUNCTION DETAILS
1) Filter sign
2) Static pressure
3) Room temperature control for indoor unit sensor
4) Auto restart
5) Room temperature sensor switching
6) Remote controller custom code
7) External input control
8) Room temperature sensor switching (Aux.)
9) Room temperature control for wired remote controller sensor
10) Heat Insulation condition (building insulation)
1) Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated
amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
Function number
11
2) Static pressure
Select the appropriate static pressure according to the installation conditions.
Function number
26
Functions
Setting value
Setting description
00
Standard (400 hours)
01
Long interval (1000 hours)
02
Short interval (200 hours)
03
No indication
Setting value
Setting description
00
0 in.WG (0 Pa)
01
0.04 in.WG (10 Pa)
02
0.08 in.WG (20 Pa)
03
0.12 in.WG (30 Pa)
04
0.16 in.WG (40 Pa)
05
0.20 in.WG (50 Pa)
06
0.24 in.WG (60 Pa)
07
0.28 in.WG (70 Pa)
08
0.32 in.WG (80 Pa)
09
0.36 in.WG (90 Pa)
31
0.10 in.WG (25 Pa) [Standard]
- (01 - 37) -
(  ... Factory setting
(  ... Factory setting)