Elation FUZE PENDANT User Manual page 21

Table of Contents

Advertisement

S Y S T E M M E N U – S T A N D A L O N E
The Standalone System Menu allows the user to define how the fixture will behave when operating
without DMX control. Color settings located in this menu also define the fixture output when operating in
1-Channel DMX Mode.
DIMMER
This function is used to set the light output intensity of the fixture, from 0% to 100% of maximum output
level.
COLOR TEMPERATURE
This function is used to set the color temperature, and ranges from 2400 to 8500 K in intervals of 100 K.
VIRTUAL COLOR
This function is used to select from a range of predefined color settings shown in the Virtual Gel Swatch
Book table on page 36.
- Swatch Book: Select a single display color from the table.
- Color Scroll: Scrolls through all the colors in forward order of the Value listed in the Virtual Gel
Swatch Book table shown on page 36. Scroll speed is adjustable from 0à22 (slowest to fastest).
- Color C-Scroll: Scrolls through all the colors in reverse order of the Value listed in the Virtual Gel
Swatch Book table shown on page 36. Scroll speed is adjustable from 0à22 (slowest to fastest).
- Random Slots: Scrolls through all the colors shown on the Virtual Gel Swatch Book table shown on
page 36 in random order. Scroll speed can be set to Fast, Medium, or Slow.
FADE TIME
This function is used to define the time span in which the fixture transitions to the output color and
intensity that have been selected in the Color Temperature and Virtual Color settings, ensuring a
smooth transition between operation in DMX mode and Standalone mode. Available Fade Time options
range from 0 seconds to 60 seconds, in 1-second intervals. The default setting for this fixture is 10
seconds.
0-10V CONTACT / ALARM CONTACT
These functions control the way that the fixture interprets the signal from the 0-10V connector. The 0-10V
CONTACT setting is used to enable or disable the fixture's ability to use the 0-10V input to determine the
intensity of light output. Please note that if this feature is enabled, the fixture will adhere to the settings
selected in the Color Temperature and Virtual Color functions of the Standalone System Menu.
Alternately, the ALARM CONTACT setting is used to enable or disable the fixture's ability to activate
Standalone mode when input is received from the 0-10V connector. DMX control will simultaneously be
disabled when the fixture enters this mode. Common uses for this feature include emergency lighting
applications or a master power switch for repair and maintenance purposes.
21

Advertisement

Table of Contents
loading

Table of Contents