At+Advdat Advertising Data; At+Advintv Advertising Interval - Ebyte E104-BT52 User Manual

Low power smd ble to serial
Hide thumbs Also See for E104-BT52:
Table of Contents

Advertisement

Inquiry
AT+ADV?
Set
AT+ADV=[para]
para(ASCII)
Parameter
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time),
Note
save when power off;
2. The slave or master-slave integrated supports broadcasting.

6.4.12 AT+ADVDAT advertising data

Command
Inquiry
AT+ADVDAT?
AT+ADVDAT=[para]
Set
Set
AT+ADVDAT1=[para]
(Do not save)
para(HEX):
Parameter
1、For ASCII、HEX
2、Length is less than 26 bytes.
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time).
Note
Save when power off;
2. The slave or master-slave integration supports broadcasting, and other roles can still be configured;
Command:41 54 2b 41 44 56 44 41 54 3d
For example,
Adv data:31 32 33 34 35 36 37 38 39 30

6.4.13 AT+ADVINTV advertising interval

Command
Inquiry
AT+ADVINTV?
Set
AT+ADVINTV=[para]
para(ASCII):20~10240
Parameter
default:1000(1S)
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time),
Note
save when power off
2. The slave or master-slave integrated supports broadcasting, other roles can still be configured;
For example,
AT+ADVINTV=1000
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd
+OK=[para]
+OK:success
+ERR=[NUM]:error
0
1
2
+OK=[para]
+OK:success
+ERR=[NUM]:error
31 32 33 34 35 36 37 38 39 30;
+OK=[para]
+OK:success
+ERR=[NUM]:error
Description
Turn off
Turn on(default)
iBeacon
Response
Response
14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents