At+Ipwr Revise Ibeacn Tx_Power; At+Name Advertising Device Name; At+ Conintv Connection Interval Configuration - Ebyte E104-BT52 User Manual

Low power smd ble to serial
Hide thumbs Also See for E104-BT52:
Table of Contents

Advertisement

6.4.17 AT+IPWR revise ibeacn tx_power

Command
Inquiry
AT+IPWR?
Set
AT+ IPWR =[para]
para(HEX): 0-0XFF
Parameter
default:0
1. Take effect immediately (if the broadcast is not turned on, or it is connected, it will take effect next time),
Note
save when power off;
2. Only the slave device supports broadcasting, other roles can still be configured;

6.4.18 AT+NAME advertising device name

Command
Inquiry
AT+NAME?
Set
AT+NAME=[para]
Set
AT+NAME1=[para]
(Do not save)
para(HEX): advertising device name,
Parameter
advertising name is not more than 22 bytes
default:E104-BT52-V1.0
1. Take effect immediately, save when power off;
Note
2. Only supported by the slave, other roles can still be configured;

6.4.19 AT+ CONINTV connection interval configuration

Command
Inquiry
AT+CONINTV?
Set
AT+CONINTV =[para]
[para](ASCII) : connection interval,value range,10~2500;
Parameter
Default:20ms
Note
Take effect immediately, save when power off.
1. The connection timeout must be greater than the connection gap;
Note
2. The device with incorrect parameters will not receive and save.
3. It is not recommended to modify the host connection gap.
AT+CONINTV=20
For example,
Connection interval 20ms
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd
Response
+OK=[para]
+OK:success
+ERR=[NUM]:error
Response
+OK=[para]
+OK:success
+ERR=[NUM]:error
Response
+OK=[ para]
+OK:success
+ERR=[NUM]:error