Alarm Signals; Electrical Connections; Final Check List - Master Bilt IHC-27 Installation & Operation Manual

Ice cream hardening/holding cabinets
Hide thumbs Also See for IHC-27:
Table of Contents

Advertisement

Here is a list of the parameters the value of which can be changed in the programming mode, as well as their ranges.
Display
Symbol
SEt
Temperature set point
Hy
Cut-out temperature is Set + Hy, Differential
LS
Minimum Temperature Set Point
Us
Maximum Temperature Set Point
ALU
High Temperature Alarm
ALL
Low Temperatyre Alarm
Us
High temperature alarm is enabled after a delay
ALd
Temperature Alarm Delay

ALARM SIGNALS

Message
"P1"
"HA"
Maximum temperature alarm
"LA"
Minimum temperature alarm
"dA"
"EA"
"CA"
Serious External alarm(i1F=bAL)
"CA"
Pressure switch alarm (i1F=PAL)
NOTE:
Probe alarm "P1" starts some seconds after the fault in the related probe; they automatically stop some seconds after the
probe restarts normal operation. Check connections before replacing the probe.
Temperature alarms "HA" and "LA" automatically stop as soon as the thermostat temperature returns to normal values
and when defrost starts.

ELECTRICAL CONNECTIONS

The controller is provided with screw terminal block or male terminals to connect cables with a cross section up to 2,5 mm
connecting cables make sure the power supply complies with the control's requirements. Separate the probe cables from the
power supply cables, from the outputs and the power connections. Do not exceed the maximum current allowed on each relay, in
case of heavier loads use a suitable external relay.

FINAL CHECK LIST

A.
Check operating pressures.
B.
Check electrical requirements of unit to supply voltage.
C.
Set temperature control for desired temperature setting.
D.
Check to make sure the compressor switch, behind the front grill, is on before start up the cabinet.
E.
Check condensing unit for vibrating or rubbing tubing. Dampen and clamp as required.
3/20 Rev. A 57-02699
Description
Cause
Room probe failure
Door open
External Alarm
Compressor output according to par. "Con" and "COF"
Outputs unchanged.
Outputs unchanged.
Compressor and fans restarts
Output unchanged
All output off
Outputs unchanged.
Factory's
Setting
-25 F
7 F
-37 F
32 F
30 F
-45 F
45 F
30 min
Outputs
2
. Before
10