The Master-Bilt TAF/TAC should not be positioned where it is directly exposed to rays of sun or near a direct source of radiant heat or air flow. This will adversely affect the case and will result in poor performance.
This is important installation, operation or service information. If you ignore the message, you may damage your cabinet. The warning and safety labels shown throughout this manual are placed on your Master-Bilt Products cabinet at the factory. Follow all warning label instructions. If any warning or safety labels become lost or damaged, call your customer service department at (800) 684-8988 for replacements.
PRE-INSTALLATION INSTRUCTIONS INSPECTION FOR SHIPPING DAMAGE You are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates for damage as soon as they arrive. If damage is noted to shipping crates or cartons or if a shortage is found, note this on the bill of lading (all copies) prior to signing.
If moisture or liquid is observed around or under a Master-Bilt cabinet, an immediated investigation should be made by qualified personnel to determine the source of the moisture or liquid. The investigation should determine if the cabinet is malfunctioning or if there is a drain pipe leaking.
CONDENSATE PAN INSTALLATION FOR TOP MOUNT CABINETS ONLY 1. Before moving cabinet into place, remove the condensate pan from the top unit compartment. Using the two screws supplied with the pan, attach the pan to the back of the cabinet at the two holes near the bottom of the plastic drain line.
FINAL CHECK LIST Check setting of defrost timer: 1. Four defrost/24 hours, with 30 minute fail safe. (TAF ONLY) Check operating pressures. Check electrical requirements of unit to supply voltage. Set temperature control for desired temperature range. Check sight glass for proper refrigerant charge. Check system for proper defrost settings and operation.
Any cabinet malfunction or housekeeping problem that creates a slip/fall hazard around or under a cabinet should be corrected immediately. MASTER-BILT PART NUMBERS The table below gives Master-Bilt part numbers. Use this chart when ordering replacement parts for your TAC/TAF cases. Description...
OWNER RESPONSIBILITY If you sell or give away your Master-Bilt cabinet you must make sure that all safety labels and the Installation - Service Manual are included with it. If you need replacement labels or manuals, Master-Bilt will provide them free.
115/60/1 CONTROL CIRCUIT TEMP. TO CONDENSING UNIT POWER TERMINALS CONT. TO LIQUID LINE SOLENOID VALVE COIL TERMINALS. CONDENSING UNIT ON SEPERATE POWER SUPPLY. EVAP. FANS TRANSFORMER DIGITAL THERM. INCANDESCENT LIGHT LIGHT SWITCH DOOR FRAME HEATER 07/19/95 WIRING DIAGRAM TAC-27-R TC27R...
J BOX CONDENSATE PAN HEATER 115/60/1 J BOX 115/60/1 CONTROL CIRCUIT TEMP. TO CONDENSING UNIT POWER TERMINALS CONT. TO LIQUID LINE SOLENOID VALVE COIL TERMINALS. CONDENSING UNIT ON SEPERATE POWER SUPPLY. EVAP. FANS TRANSFORMER DIGITAL THERM. INCANDESCENT LIGHT LIGHT LIGHT SWITCH SWITCH DOOR...
J BOX CONDENSATE PAN HEATER 115/60/1 115/60/1 CONTROL CIRCUIT TEMP. CONT. TO CONDENSING UNIT POWER TERMINALS TO LIQUID LINE SOLENOID VALVE COIL TERMINALS (CONDENSING UNIT ON SEPERATE POWER SUPPLY) EVAP. FANS TRANSFORMER DIGITAL THERM. INCANDESCENT INCANDESCENT LIGHT LIGHT LIGHT LIGHT LIGHT SWITCH SWITCH...