FRONT PANEL DISPLAY MENUS

This unit has additional menus that are displayed in the
front panel display.

Advanced setup menu

This menu offers additional operations to adjust and
customize the way this unit operates. Change the settings
to reflect the needs of your listening environment.
1
Make sure this unit is in the standby mode.
2
On the front panel, while holding down
STRAIGHT/EFFECT, press STANDBY/ON.
STRAIGHT
EFFECT
3
Rotate PROGRAM to select the desired
operation.
The name of the selected operation appears in the
front panel display.
4
Press STRAIGHT/EFFECT to change the
setting.
5
Press STANDBY/ON to save the new setting
This unit enters the standby mode.
y
The new setting is activated next time you turn on the power of
this unit.
84
FRONT PANEL DISPLAY MENUS
STANDBY
/ON
PROGRAM
SP IMP. (Speaker impedance)
Use to set the impedance of this unit so that it matches that
of your speakers.
Choices: 6ΩMIN, 8ΩMIN
• Select "6ΩMIN" for speakers that are 6 ohm or higher.
• Select "8ΩMIN" for speakers that are 8 ohm or higher.
PRESET (Factory preset)
Use to reset all of this unit's parameters to the initial
factory settings with the exception of System Memory and
Auto Setup settings.
Choices: CANCEL, RESET
• Select "CANCEL" if you do not want to reset this
unit's parameters.
• Select "RESET" to reset this unit's parameters.
REMOTE (Remote control ID)
Use to set this unit's ID for remote control recognition
(see page 71).
Choices: ID1, ID2
• Select "ID1" when the remote control amplifier library
code is set to "2000" or "2001".
• Select "ID2" when the remote control amplifier library
code is set to "2002" or "2003".
FAN MODE (Fan operation mode)
Use to set the operation of this unit's cooling fan.
Choices: AUTO, CONT
• Select "AUTO" to set the fan to operate automatically
according to the temperature of this unit.
• Select "CONT" to set the fan to operate continuously
regardless of the temperature of this unit.
TU (Tuner frequency step)
(Asia and General models only)
Use to set the tuner frequency step according to the
frequency spacing in your area.
Choices: AM10/FM100, AM9/FM50
• Select "AM10/FM100" for North, Central and South
America.
• Select "AM9/FM50" for all other areas.