Project Diversion Procedures By Engineering Environment - Mitsubishi Electric MELSEC iQ-R Series Migration Manual

Servo system controller motion controller
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

2. DETAILS OF MIGRATION FROM Q17nCPUN(-T) TO RnMTCPU

2.4.3 Project diversion procedures by engineering environment

The following shows the project diversion procedures for PLC CPU and Motion CPU.
(1) Procedures for PLC CPU projects diversion by MELSOFT GX Works3
MELSOFT GX Works3 can read projects created in MELSOFT GX Works2.
If the PLC CPU is other than the following models, the programmable controller type needs to
be changed to universal models.
• Universal model QCPU
• High-speed universal model QCPU
• Universal model process CPU
Refer to "GX Works2 Version 1 Operating Manual (Common)" for restrictions on the
programmable controller type changes.
In addition, refer to the following Technical Bulletins for details of the programmable controller
type changes.
(Note): Contact your local sales office for details.
• Method of replacing Basic model QCPU with Universal model QCPU (FA-A-0054)
• Method of replacing High Performance model QCPU with Universal model QCPU
(FA-A-0001)
• Method of replacing High Performance model QCPU with Universal model QCPU
(Introduction) (FA-A-0209)
[Procedures when projects in which universal model QCPU is set is diverted to MELSOFT
GX Works3]
Refer to "GX Works3 Operating Manual" for details of replacing MELSOFT GX Works2
projects as those for MELSOFT GX Works3.
1) Start MELSOFT GX Works3. Select [Open Other Format File] - [GX Works2 Format] -
[Open Project...] in "Project" menu.
2 - 31