The power supply to the water heater must not be switched on until the solar storage tank is filled with
water.
MEGGER READING
It is not mandatory to conduct a megger test on a plug in appliance, however if a megger test is conducted on
this water heater, then the following should be noted.
Warning: This water heater contains electronic equipment and 500 V insulation tests must only be
conducted between either active and earth or neutral and earth. An active to neutral test WILL damage the
electronics.
An insulation test result of approximately 660 KΩ for this water heater is normal.
AS/NZS 3000 permits an insulation test result less than 1 MΩ where the appliance is approved to a Standard
applicable to the appliance.
This model water heater is categorised as a 'stationary Class 1 motor operated appliance' and satisfies the
requirements of AS/NZS 60335.1 for leakage current and electric strength. Therefore, this model water heater
complies with the insulation resistance requirements of AS/NZS 3000.
ELECTRICAL CONNECTION
All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the
Wiring Rules AS/NZS 3000 and all local codes and regulatory authority requirements.
Warning: Temperature controllers or an EZiSET kit must not be fitted to an in-series gas booster as part
of a solar water heater system because water at a temperature much higher than the controller setting can be
delivered.
The solar storage tank and gas booster both require a 220 V – 240 V a.c., 50 Hz mains power supply for
operation. The solar storage tank and gas booster are both supplied with a 1.8 metre power cord and each
require their own switched general purpose outlet (GPO) to be located within 1.2 metres of the installation.
Two GPOs are required and each GPO must have a continuous power supply. The GPOs are required to be
weatherproof if installed outdoors.
The power consumption of the water heater is:
Component
Solar controller
Solar pump
Gas booster
The solar storage tank and gas booster will only operate on a sine wave at 50 Hz. Devices generating a square
wave cannot be used to supply power to the water heater.
CONNECTIONS – ELECTRICAL
Power
Comments
consumption
3 Watts
Constant load
Maximum load at solar heating cycle start up
165 Watts
(for approximately two (2) minutes)
50 Watts
Average load during the solar heating cycle
59 Watts
Burner on, anti-frost device inactive (26L booster)
127 Watts
Burner on, anti-frost device active (26L booster)