CONNECTIONS – ELECTRICAL
HOT SENSOR LEAD
House the hot sensor lead at the water heater in the flexible conduit provided and secure the conduit in the
cut out on the tab located behind the upper front cover. Connect the hot sensor cable to the hot sensor cable
connector located on the tab behind the upper front cover. Secure the hot sensor lead to the water heater
jacket to prevent possible damage.
TEMPERATURE SETTING
The gas booster outlet temperature setting can be adjusted. The adjustment procedure is detailed in the
Owner's Guide and Installation Instructions supplied with the gas booster. The factory preset outlet booster
temperature setting is 60°C.
Note: AS 3498 requires that a water heater provides the means to inhibit the growth of Legionella bacteria in
potable water. The in-series gas booster can satisfy this AS 3498 requirement provided it is energised, the
booster preset outlet temperature setting is 70°C or higher and a remote temperature controller or an EZiSET
kit is not used.
WIRING DIAGRAM