Rheem Solar Premier Loline 596270 Owner's Manual And Installation Instructions page 59

Gas boosted water heater
Hide thumbs Also See for Solar Premier Loline 596270:
Table of Contents

Advertisement

Determine the correct amount of water to be added to or closed circuit fluid to be drained from the heat
17.
exchanger if the dynamic level is either below the text marking "MINIMUM FLUID LEVEL WITH PUMP
OPERATING" or more than 150 mm above this mark.
Each 100 mm of fluid level height is equivalent to three (3) litres of closed circuit fluid.
20 mm
40 mm
60 mm
Mark the required closed circuit fluid level to be obtained on the side of the solar storage tank with a
non-permanent marker beside the clear hose, in relation to the static level marked on the side of the
solar storage tank during
E.g.: If the dynamic level is 30 mm below the text marking, then place a mark 30 mm above the static
level marked on the side of the solar storage tank in
water to the heat exchanger.
E.g.: If the dynamic level is 180 mm above the text marking, then place a mark at least 30 mm, but
no more than 180 mm, below the static level marked on the side of the solar storage tank. It would
be necessary to drain between one litre and five litres of closed circuit fluid from the heat exchanger.
mark between
'Y mm' and
'Y + 150 mm'
below static mark
'Y mm' greater
than 150 mm
above text
marking
150 mm
above text
marking
0.6 litres
80 mm
1.2 litres
100 mm
1.8 litres
120 mm
step
8.
mark static level to achieve
static level marked on tank during step 8
mark static level to achieve
If the dynamic fluid level is greater than
150 mm above the text marking, then place
a mark below the static level marked on the
tank of between equal to this distance and
this distance plus 150 mm.
MINIMUM FLUID LEVEL WITH PUMP OPERATING
If the dynamic fluid level is below the text marking,
then place a mark equal to this distance above the
static level marked on the tank
2.4 litres
3.0 litres
3.6 litres
step
8. It would be necessary to add one litre of
59
COMMISSIONING
140 mm
4.2 litres
160 mm
4.8 litres
180 mm
5.4 litres
mark
'X mm'
above
static mark
'X mm'
below text
marking

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents