The system controller indicates a runaway fault condition when the sensor senses a pump cycle rate greater than 10 strokes in a 20-sec period. 10018479/10018480 Figure 1 Air Motor Sensors Part 1615707−01 E 2019 Nordson Corporation...
Page 2
(3) to the 4-pin Y cable. NOTE: f optional stop position sensor is not equipped, connect the cable from the pump stroke/runaway sensor directly to the hose module. 5.25 in. 2.50 in. 10018479/10018480 Figure 2 Air Motor Sensor Installation Part 1615707−01 E 2019 Nordson Corporation...
Page 3
4-pin Y cable (4). NOTE: f optional stop position sensor is not equipped, connect the cable from the pump stroke/runaway sensor directly to the hose module. 5.25 in. 2.50 in. 10018479/10018480 Figure 3 Air Motor Sensor Repair Part 1615707−01 E 2019 Nordson Corporation...
Page 4
S CABLE TIE, 3.9 in., 185_ F/85_ C, nylon, 939110 939110 natural Issued 06/19 Original copyright date 2019. Rhino, Nordson, and the Nordson logo are registered trademarks of Nordson Corporation. All other trademarks are the property of their respective owners. Part 1615707−01 E 2019 Nordson Corporation...