Lock Responses

The tables below summarize how the red and green LEDs are flashed individually,
simultaneously, or in combination to indicate various conditions. Each LED flash is
accompanied by a beep for audio reinforcement.
Flashes
Green LED
Continuous Present Card
1
Keystroke Entry
2
Input Accepted/DST Activated
3
Lock Ready to Open/
PROX Added Manually
4
Standard Time Activated
Flashes
Green / Red Sequence
Continuous Download in Progress
1
Clear Key Depression
2
Device Error **
**
Contact PowerLever Technical Support for assistance.
One simultaneous flash of the green and red LEDs accompanied by a beep
indicates that the lock is powered for opening.
When power drops below a sufficient level for operation, the lock will continually
beep and flash the red LED. At this point, the operator has 5 seconds in which
to regenerate power to a sufficient level before the lock will systematically
shutdown. To regenerate power, depress the outside lever fully and then
release it.
After each accepted step of an operation, two flashes of the green LED display
and two beeps sound, prompting you to enter additional information for the next
step of the operation. The User must wait for these prompts before proceed-
ing.
After you have completed all the steps of an operation, two simultaneous
flashes of the green and red LED display and two beeps sound if the operation
is successful. Two red flashes display and two beeps sound if the operation is
unsuccessful, and you will need to re-key the operation which caused the error.
Red LED
Low Power
General Error
Bad Attempt to Open
Simultaneous Green-Red
Lock Powered
Procedure End; Re-lock or
Tamper Shutdown Expired