GFA TS 959 Series Installation Instructions Manual

GFA TS 959 Series Installation Instructions Manual

Door control

Advertisement

Installation instructions
Door control
TS 959
Hold-to-run control
Version: 51171547
– en –
Status: j / 01.2020
0 0 00 0 00 00 0 0 5 11 7 15 4 7 XXXXX

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TS 959 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GFA TS 959 Series

  • Page 1 Installation instructions Door control TS 959 Hold-to-run control Version: 51171547 – en – Status: j / 01.2020 0 0 00 0 00 00 0 0 5 11 7 15 4 7 XXXXX...
  • Page 2 GfA ELEKTROMATEN GmbH & Co. KG Wiesenstraße 81 • 40549 Düsseldorf www.gfa-elektromaten.de info@gfa-elektromaten.de...
  • Page 3: Table Of Contents

    Safety functions ......................20   Maintenance cycle counter ..................... 21   Readout of data memory ....................22   Deleting of all settings / Readout GfA stick ..............22   Safety devices ......................23     X2: Input, door safety switch ................... 23  ...
  • Page 4 Functional description ....................24     X1: Mains supply of the control and supply of external devices ........24   X5: Input, control device ....................25   Door operating mode "Extended hold-to-run" ..............25   Potential-free X20 Relay contact ..................25  ...
  • Page 5: General Safety Information

    1 General safety information Specified use The door control is intended for a power-operated door with a drive unit (NES/DES GfA limit switch system). The safe operation is only guaranteed with specified normal use. The drive unit is to be protected from rain, moisture and aggressive ambient conditions.
  • Page 6: Technical Data

    +0 °C …..+50 °C Air humidity, non-condensing up to 93 % Protection class of housing with CEE-plug IP 54 / IP 65 Protection class of housing IP 65 NES (mechanical limit switch) Compatible GfA - limit switch DES (digital limit switch)
  • Page 7: Mechanical Installation

    3 Mechanical installation Control installation!  Indoor use only  Mounting only on even ground that is free of vibration  Only mount in the vertical position  Door must be in clear view from place of installation Requirements The permissible loads on walls, mountings, connection and transmission elements must not be exceeded.
  • Page 8: Electrical Installation

    4 Electrical installation Warning - Danger to life due to electrical current!  Disconnect the cables (mains OFF) and check that the supply is off  Observe the applicable regulations and standards  Ensure proper electrical connection  Use suitable tools On-site backup fuse and disconnector unit! ...
  • Page 9: Connection Cable Connection Overview

    Connection cable connection overview Ⓐ Ⓑ Ⓒ Ⓓ DES → X12 DES MOT → Core Description: Core Term. Description: ① 5/wh ① +24 V safety circuit ① Phase W ② 6/bn ② Channel B (RS485) ② Phase V ③ 7/gn ③...
  • Page 10: Limit Switch Configuration, Screwable Version Up To Year Of Construction In 1997

    Limit switch configuration, screwable version up to year of construction in 1997 4 (N) Thermal contact Limit switch board Rectifier Emergency OPEN limit switch Motor Emergency CLOSE limit switch Emergency manual operation OPEN limit switch Connection cable CLOSE limit switch Spring-loaded brake Auxiliary limit switch Auxiliary limit switch...
  • Page 11: Carrying Out The Electrical Installation

    Carrying out the electrical installation ▶ Remove covers. ▶ Open cable entry ① or ②. ▶ Insert and connect connection cable in the open cable entry ① (from below) or ② (from above). ▶ Properly tighten cable glands. Avoid damage to parts! ...
  • Page 12: Mains Supply

    Mains supply 3~, N, PE 3~, PE 1~, N, PE, sym. 1~, N, PE, asym. 230 / 400 V 230 V 230 / 400 V 230 V 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz L1 L2 L3 N PE L1 L2 L3 N PE...
  • Page 13: Overview Of Control

    Overview of control DES/ 5.1 5.2 5.3 5.4 F1 = 1,6A t Mains supply DES/ DES or NES limit switch socket Door safety switch Micro-fuse 1.6 A time-lag Emergency STOP control device Motor socket Control device, external three push-button Selector switch Potential-free relay contact OPEN push-button STOP push-button...
  • Page 14: Commissioning Of The Control

    5 Commissioning of the control ▶ Supply cables Insert / switch on DES: Rapid adjustment of final limit positions 1. Check output rotating direction 2. Move to OPEN final limit position 3. Save OPEN final limit position 4. Move to CLOSE final limit position 5.
  • Page 15: Nes: Rapid Adjustment Of Final Limit Positions

    Observe the installation instructions of the drive unit!  For adjusting the mechanical limit switch, see the drive unit installation instructions NES: Rapid adjustment of final limit positions 1. Check output rotating direction 2. Move to OPEN final limit position and adjust S3 OPEN limit switch 3.
  • Page 16: Advanced Electrical Installation

    6 Advanced electrical installation Connection of door safety switches X2 Connection of door safety switches X2 Pass-door switch / slack-rope switch suitable for Performance Level c (PLc) Junction box switch Mains supply Input for door safety switch S30a Slack-rope switch (NC contact) S30b Electronic pass-door switch (Entrysense) S30a...
  • Page 17: External Supply X1

    External supply X1 Emergency STOP X3 X20 Relay contact Relay contact X20 External supply X1 Emergency STOP X3 F1 = 1,6A t A16 Relay A1 External device A2 Control device F1 Micro-fuse 1,6 A Emergency STOP External Control device X5 External control device X5 Three push button A4 Key push-button...
  • Page 18: Control Programming

    7 Control programming 1. Start programming Note!  Complete programming is only possible after setting the final limit positions. 2. Select menu item and confirm 3.a) Set and store functions 3.b) Set and store positions (DES) 4. Exit programming...
  • Page 19: Door Operating Modes

    8 Table menu items Door operating modes Door operating modes Door operating mode Hold-to-run OPEN Hold-to-run CLOSE Self-hold OPEN Hold-to-run CLOSE Extended hold-to-run For NES: Set the S5 limit switch right before the CLOSE final limit position Output rotating direction Maintain output rotating direction Change output rotating direction Door positions...
  • Page 20: Door Functions

    Door functions Door functions Relay function on X20 Impuls contact for 1 second Permanent contact Red lamp, permanently lit during door movement OPEN final limit position 3 seconds permanent light CLOSE final limit position 3 seconds permanent light Red lamp, permanently lit during door movement OPEN final limit position 3 seconds permanent light CLOSE final limit position...
  • Page 21: Maintenance Cycle Counter

    Maintenance cycle counter Maintenance cycle counter Maintenance cycle preselection 01-99 corresponds to 1,000 to 99,000 cycles Cycles are counted down Reaction upon reaching "0" Status indication "CS" appears in turns with value set by menu item 8.5. Changeover to "hold-to-run" door operating mode. Status indication "CS" appears in turns with value set by menu item 8.5.
  • Page 22: Readout Of Data Memory

    Cycle counter of the last change in programming Number of activations of slack-rope, pass-door switch Software version The firmware version of the control is displayed Deleting of all settings / Readout GfA stick Deleting / Readout Deleting of all settings Activating GfA stick...
  • Page 23: Safety Devices

    9 Safety devices X2: Input, door safety switch The door safety switch is installed on the door and connected to the door control via the spiral cable. Function Reaction upon activation Switching contact is interrupted: Door stop Slack-rope switch / pass-door switch Switching contact is closed: Door is ready for operation Door safety switch...
  • Page 24: X3: Input, Emergency Stop

    X3: Input, emergency STOP The Emergency STOP control device is connected to a safety circuit with Performance Level c (Plc) according to ISO 13849-1. Connection of an emergency STOP control device as per EN 13850 or an evaluation unit for an anti-trap safety device.
  • Page 25: X5: Input, Control Device

    X5: Input, control device Warning! ▶ "Hold-to-run" door operating mode: The door must be fully visible from the operating point Note! ▶ Application without STOP push-button: Connect wire link X5.1 to wire link X5.2 Door operating mode "Extended hold-to-run" Menu item 0.1 Function ".5". At the door operating mode "Extended hold-to-run", the CLOSE-button must be pressed until door final position CLOSED is reached.
  • Page 26: Force Monitoring (Des Only)

    Force monitoring (DES only) Menu item 3.1: The force monitoring can only be used with fully balanced doors and drive units with DES. It should be able to detect when persons are moving with the door. Warning!  The force monitoring is no substitute for safety measures in providing protection against the trapping hazard Function Force monitoring...
  • Page 27: Travel Time Monitoring (Nes Only)

    Travel time monitoring (NES only) Menu item 3.3 The set travel time is automatically compared with the time measured for movement between the final limit positions. If the travel time is exceeded, the F5.6 fault indication appears. Fault indication F5.6 is reset by closing the door. Note! ...
  • Page 28: Status Display

    11 Status display Faults Faults Display: "F" and code Code Fault description Fault causes and fault correction Check door safety switch. Terminals X2.1 – X2.2 are open. Check whether the connection cable is Slack-rope switch/Pass-door contact is open. connected. Check emergency manual operation. Check door Open safety circuit (DES) and door drive unit for stalling.
  • Page 29 Faults Display: "F" and code Code Fault description Fault causes and fault correction Limit switch system has changed over from Reset of control via menu item "9.5". DES to NES without the control being reset. Execute fault clearance trough movement Internal plausibility error.
  • Page 30: Commands

    Commands Commands Display: "E" and code Code Command description An OPEN-command is present. Inputs X5.3 A STOP command is present. Inputs X5.2 A CLOSE command is present. Inputs X5.4...
  • Page 31: Status Indications

    Status indications Status indications Status Description display Preset value for maintenance cycle counter reached. Dot on left is not lit: Control circuit has a short circuit or is overloaded. Function for changing the rotating direction is activated, only possible during initial operation. Change of rotating direction has been carried out, only possible during initial operation.
  • Page 32: Explanation Of Symbols

    12 Explanation of symbols Symbol Explanation Prompt: Read installation instructions Prompt: Check Prompt: Note Prompt: Note the setting of the menu below Factory setting of the menu Factory setting of the menu, value on the right Factory setting of the minimum limit, dependent on drive unit Factory setting of the maximum limit, dependent on drive unit Setting range Prompt: Select menu item or value,...
  • Page 33 Symbol Explanation Prompt: Setting via OPEN/CLOSE built in push-button; Use OPEN push-button to increase value, CLOSE push-button to decrease value Prompt: Press stop button once via built in push-button Prompt: Save, press stop button once via built in push-button Prompt: Save, press stop button for three seconds via built in push-button Prompt: Reset the control, press stop button for three seconds via built in push-button...
  • Page 34: Declaration Of Incorporation / Declaration Of Conformity

    EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU The following requirements from Appendix I of GfA ELEKTROMATEN GmbH & Co. KG the Machinery Directive 2006/42/EC are met: declare under our sole responsibility that the 1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.2, 1.2.3, 1.2.4.2,...